Signalling and Telecommunication for the Junior Engineer Papers: Signals, Track Circuits, Transmission Lines, Antennas, Digital Transmission and Optical Fibre

The Signal and Telecommunication (S&T) discipline keeps trains apart and keeps the railway talking. It overlaps the telecommunication parts of the other Junior Engineer and Scientific Assistant lists: antennas, wave propagation, modulation, multiplexing, digital communication and radio. This chapter teaches the standing first-diploma content, in two halves: how railway signalling achieves safety, and how a telecommunication link is engineered. It rests on standing subject matter, not on a notice, and does not state any current railway project figure.
Overview

1. Signals, fail-safe design and block working

1 min read · 4 parts

A railway signal tells the driver whether the line ahead is clear. The governing idea is the fail-safe principle: any failure must push the system to the restrictive state, a red signal, never to a clear one. A failure that leaves the signal more restrictive than it should be is a right-side failure; one that gives a less restrictive indication is a dangerous wrong-side failure. This is why signalling relays, track circuits and lamps are arranged so that loss of power or a broken wire drops the signal to danger.

Aspect (colour light)Meaning to the driver
RedStop
YellowCaution: be ready to stop at the next signal
Two yellowsAttention: proceed, and expect the next signal to show yellow (multiple-aspect territory)
GreenProceed at the permitted speed
  • Track circuit: a low-voltage current runs through the rails to a relay. A train's axles short the rails, the relay drops and the signal goes red; a broken rail also drops the relay, which is fail-safe.
  • Axle counter: counts axles into and out of a section and needs no insulated joints, so it suits long sections and wet or poorly ballasted track.
  • Interlocking prevents conflicting moves: a signal cannot be cleared unless the points are set and locked for that route. Mechanical, relay and electronic interlocking do the same job with different technology.
  • Block working keeps one train in a section between stations: in the absolute block system the station ahead must give "line clear" before the previous station lets a train in; automatic block signalling divides the line into track-circuited sections with signals.

A railway signal tells the driver whether the line ahead is clear. The governing idea is the fail-safe principle: any failure must push the system to the restrictive state, a red signal…

2. Transmission lines, antennas and propagation

1 min read · 1 part

A transmission line carries signals between equipment, and its characteristic impedance Z₀ = √(L ÷ C) is what a load must match to take all the power. A line of 0.25 µH and 100 pF per metre has Z₀ = √(0.25 × 10⁻⁶ ÷ 100 × 10⁻¹²) = 50 Ω. A mismatched load reflects part of the wave: the reflection coefficient is Γ = (Z_L − Z₀) ÷ (Z_L + Z₀), and the voltage standing wave ratio is VSWR = (1 + |Γ|) ÷ (1 − |Γ|). A 100 Ω load on a 50 Ω line has Γ = 1/3 and VSWR = 2; a perfect match gives VSWR = 1.

An antenna turns guided waves into radiated waves and back. A half-wave dipole is λ ÷ 2 long, where λ = c ÷ f: at 100 MHz the wavelength is 3 m and the dipole 1.5 m. Directivity and gain describe how strongly it favours one direction; a Yagi gives a directional beam and a parabolic dish a very narrow one at microwave frequencies. Waves travel as ground waves (low frequencies, following the earth), sky waves (HF, refracted by the ionosphere, with a skip zone) or space waves (VHF and above, line of sight). The line-of-sight range between two antennas of heights h₁ and h₂ metres is about 3.57(√h₁ + √h₂) km, so two 25 m masts reach about 36 km.

⚠️ Line of sight is not the earth's curve alone
The 3.57 coefficient already includes a standard allowance for atmospheric refraction; the geometric horizon coefficient is smaller. Questions that quote the formula expect the 3.57 form with heights in metres and range in kilometres.

A transmission line carries signals between equipment, and its characteristic impedance Z₀ = √(L ÷ C) is what a load must match to take all the power. A line of 0.25 µH and 100 pF per metre…

3. Digital transmission, multiplexing and optical fibre

1 min read · 1 part

Speech is digitised by pulse code modulation: sample at 8 kHz (twice the 4 kHz voice bandwidth, from the sampling theorem) and code each sample in 8 bits, giving 8,000 × 8 = 64 kbit/s per channel. Time-division multiplexing interleaves channels: 32 time slots of 64 kbit/s make the primary E1 stream at 2.048 Mbit/s, of which 30 slots carry speech and two carry framing and signalling. Frequency-division multiplexing instead gives each channel its own band.

An optical fibre guides light by total internal reflection at the boundary between a higher-index core and lower-index cladding. Single-mode fibre has a very thin core, carries one mode, has low dispersion and serves long distances; multimode fibre has a thicker core and suits short links. Fibre loss is quoted in dB per kilometre, typically near 0.35 dB/km at 1,310 nm and lower at 1,550 nm. Over 40 km at 0.35 dB/km the loss is 14 dB, which is a power ratio of 10^1.4 ≈ 25. Because decibels add, a link budget simply adds source power and subtracts every loss.

ℹ️ Railway radio
Railways use VHF and UHF radio for station and section working, and GSM-R, a railway-specific form of GSM, for train voice and control data. The principles above (modulation, multiplexing, link budget) are the same.

Speech is digitised by pulse code modulation: sample at 8 kHz (twice the 4 kHz voice bandwidth, from the sampling theorem) and code each sample in 8 bits, giving 8,000 × 8 = 64 kbit/s per…

4. Telephony, traffic and power for signalling equipment

1 min read

Telephone traffic is measured in erlangs, the average number of circuits busy at once: calls per hour × mean call duration in hours. 100 calls an hour of 3 minutes each is 100 × 3 ÷ 60 = 5 erlangs, so a group of lines must carry at least 5 simultaneous calls plus a margin set by the permitted blocking probability. The decibel is 10 log₁₀ of a power ratio (20 log₁₀ for voltage or current), and it turns multiplication of gains and losses into addition.

  • Signalling equipment needs power that never fails: a mains supply backed by a battery bank and charger, with a float-charged lead-acid cell at about 2 V nominal per cell and an inverter or UPS for electronic interlocking.
  • Earthing and surge protection guard sensitive electronics from lightning and traction-current induction, which is a particular hazard on electrified track.
  • Cables carrying signalling circuits are routed and screened to avoid induction from the high-voltage overhead line.
  • Exchanges switch calls; digital exchanges switch the 64 kbit/s time slots themselves, so voice and data share one network.

Telephone traffic is measured in erlangs, the average number of circuits busy at once: calls per hour × mean call duration in hours. 100 calls an hour of 3 minutes each is 100 × 3 ÷ 60 = 5…

5. Worked problems: decibels, sampling and fibre loss

1 min read · 1 part

Decibels turn multiplication into addition. A power ratio is 10 log₁₀(P₂ ÷ P₁) dB, and a voltage or current ratio into the same resistance is 20 log₁₀. A doubling of power is about +3 dB and a tenfold increase is +10 dB. Stages in a chain simply add: an amplifier of +30 dB followed by a cable of −12 dB gives +18 dB overall, a power ratio of 10^1.8 = 63. An input of 2 mW and an output of 200 mW is a ratio of 100, which is +20 dB.

ItemRule or figureExample
Nyquist samplingSampling rate ≥ 2 × highest frequencyA 4 kHz speech channel is sampled at 8,000 per second
PCM voice channel8,000 samples × 8 bits64 kbit/s
E1 primary group32 time slots × 64 kbit/s2.048 Mbit/s, of which 30 slots carry speech
Fibre attenuationLoss (dB) = α × length0.35 dB/km over 20 km is 7 dB

For the fibre, a loss of 7 dB leaves 10^(−0.7) = 0.20 of the power, so 1 mW launched arrives as about 0.2 mW. Because decibels are logarithmic, a 10 dB loss leaves one-tenth and a 20 dB loss one-hundredth.

⚠️ Do not add decibels to watts
A gain in dB is added to another gain in dB, but never to a power in watts. To apply a gain to a power, convert the dB to a ratio first, or express the power in dBm and then add.

Decibels turn multiplication into addition. A power ratio is 10 log₁₀(P₂ ÷ P₁) dB, and a voltage or current ratio into the same resistance is 20 log₁₀. A doubling of power is about +3 dB…

Second Pass: Decibel Rules, Wavelength, PCM Rate, Erlang and Fibre Budget

1 min read · 2 parts

Decibel rules: power ratio of 2 is 3 dB, of 10 is 10 dB and of 100 is 20 dB; for voltage ratios the multiplier is 20 log. Wavelength λ = c/f. A PCM voice channel samples at 8 kHz with 8 bits, giving 64 kbit/s. Offered traffic in erlangs is calls per hour × average duration in hours, and a fibre budget subtracts loss in dB.

Worked values
ItemWorkingAnswer
Power ratio 10010 log 10020 dB
75 MHz quarter-waveλ = 4 m; λ/41 m
30 calls/h, 4 min each30 × 4/602 erlangs
2 mW into 3 dB loss2 × 1/21 mW
🧠 Three decibel anchors
Remember 3 dB is a factor of 2, 10 dB a factor of 10 and 20 dB a factor of 100 in power. A 3 dB loss halves the power: 2 mW becomes 1 mW; a 13 dB gain is 10 × 2 = 20 times.

Decibel rules: power ratio of 2 is 3 dB, of 10 is 10 dB and of 100 is 20 dB; for voltage ratios the multiplier is 20 log. Wavelength λ = c/f. A PCM voice channel samples at 8 kHz with 8…

Key takeaways

  • Signalling is fail-safe: any failure must give a restrictive aspect; track circuits and axle counters detect occupation, interlocking prevents conflicting moves.
  • Γ = (Z_L − Z₀) ÷ (Z_L + Z₀) and VSWR = (1 + |Γ|) ÷ (1 − |Γ|); a match gives VSWR = 1.
  • A half-wave dipole is λ ÷ 2 with λ = c ÷ f; line-of-sight range is about 3.57(√h₁ + √h₂) km.
  • PCM gives 64 kbit/s per voice channel and E1 is 32 slots, 2.048 Mbit/s; fibre loss in dB adds linearly along the route.
  • Traffic in erlangs = calls per hour × duration in hours; the decibel turns gain and loss multiplication into addition.
  • Decibels add along a chain; sampling must be at least twice the highest frequency, so a 64 kbit/s voice channel and a 2.048 Mbit/s E1 of 32 slots.

Practice questions (25)

Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.

  1. A signalling failure that leaves a signal showing a more restrictive aspect than necessary is called:

    1. a right-side failure
    2. a wrong-side failure
    3. an interlocking failure
    4. a block failure
    Show answer

    Answer: A — a right-side failure

    Fail-safe design aims to make every failure a right-side one, such as a red signal when the lamp or the supply fails. A wrong-side failure gives a less restrictive aspect than the line conditions allow and is the dangerous kind the design is built to prevent.
  2. In a track circuit, when a train enters the section the track relay:

    1. drops because the wheels and axles short the rails
    2. is energised more strongly
    3. is unaffected
    4. is disconnected from the battery by hand
    Show answer

    Answer: A — drops because the wheels and axles short the rails

    The wheels and axles form a low-resistance path across the two rails, diverting current away from the relay coil, which drops out and holds the signal at red. A broken rail or failed supply has the same effect, which is what makes the circuit fail-safe.
  3. A 100 Ω load is connected to a 50 Ω transmission line. The VSWR on the line is:

    1. 0.5
    2. 1
    3. 2
    4. 3
    Show answer

    Answer: C — 2

    Γ = (100 − 50) ÷ (100 + 50) = 1/3, so VSWR = (1 + 1/3) ÷ (1 − 1/3) = 2. For a purely resistive load the VSWR is also simply the larger of Z_L ÷ Z₀ and Z₀ ÷ Z_L, which here is 100 ÷ 50 = 2. VSWR can never be below 1.
Show the other 22 questions
  1. The length of a half-wave dipole for a frequency of 100 MHz (c = 3 × 10⁸ m/s) is:

    1. 3 m
    2. 1.5 m
    3. 0.75 m
    4. 6 m
    Show answer

    Answer: B — 1.5 m

    The wavelength is c ÷ f = 3 × 10⁸ ÷ 10⁸ = 3 m and the half-wave dipole is half of it, 1.5 m. Quoting 3 m gives the full wavelength, and 0.75 m would be a quarter-wave element.
  2. Using range = 3.57(√h₁ + √h₂) km with heights in metres, the line-of-sight range between two antennas each 25 m high is about:

    1. 18 km
    2. 36 km
    3. 71 km
    4. 9 km
    Show answer

    Answer: B — 36 km

    √25 = 5 for each mast, so the range is 3.57 × (5 + 5) = 35.7 km, about 36 km. Using only one mast (about 18 km) forgets that both antennas see the horizon, and each adds its own share.
  3. A primary E1 digital stream with 32 time slots of 64 kbit/s each has a bit rate of:

    1. 1.544 Mbit/s
    2. 2.048 Mbit/s
    3. 64 Mbit/s
    4. 8.192 Mbit/s
    Show answer

    Answer: B — 2.048 Mbit/s

    32 × 64,000 = 2,048,000 bit/s = 2.048 Mbit/s. The 1.544 Mbit/s rate belongs to the North American T1 system, which carries 24 channels. Of the 32 E1 slots, 30 carry speech.
  4. An optical fibre link 40 km long has a loss of 0.35 dB/km. The total fibre loss, and the power ratio it represents, are about:

    1. 14 dB, a factor of about 25
    2. 14 dB, a factor of 14
    3. 3.5 dB, a factor of 2
    4. 1.4 dB, a factor of 1.4
    Show answer

    Answer: A — 14 dB, a factor of about 25

    Decibels add along the route: 0.35 × 40 = 14 dB. The power ratio is 10^(14/10) = 10^1.4 ≈ 25, so only about 4% of the launched power arrives. A decibel count is not a ratio, and the second option makes that confusion.
  5. A group of lines receives 100 calls an hour, each lasting 3 minutes on average. The offered traffic is:

    1. 3 erlangs
    2. 5 erlangs
    3. 300 erlangs
    4. 0.05 erlang
    Show answer

    Answer: B — 5 erlangs

    Traffic in erlangs is calls per hour times the mean duration in hours: 100 × (3 ÷ 60) = 5. Leaving the duration in minutes (300) gives call-minutes per hour, not erlangs.
  6. Light of 1 mW is launched into an optical fibre of length 20 km whose attenuation is 0.35 dB/km. The power received is nearest to:

    1. 0.2 mW
    2. 0.65 mW
    3. 0.07 mW
    4. 0.35 mW
    Show answer

    Answer: A — 0.2 mW

    The loss is 0.35 × 20 = 7 dB, a power ratio of 10^(−0.7) = 0.2, so 0.2 mW arrives. Treating 7 dB as a loss of 7 mW (or 35%) ignores the logarithmic scale.
  7. An amplifier of gain 30 dB feeds a cable of loss 12 dB. The overall power ratio (output ÷ input) is nearest to:

    1. 63
    2. 18
    3. 1,000
    4. 8
    Show answer

    Answer: A — 63

    The net gain is 30 − 12 = 18 dB, and 10^(18/10) = 63. Quoting 18 gives the decibel figure, not the ratio; 1,000 is the amplifier alone.
  8. A power ratio of 100 expressed in decibels is:

    1. 20 dB
    2. 10 dB
    3. 40 dB
    4. 100 dB
    Show answer

    Answer: A — 20 dB

    dB = 10 log₁₀(100) = 20. A voltage ratio of 100 would be 40 dB, using 20 log.
  9. A quarter-wave monopole antenna is to be built for 75 MHz (c = 3 × 10⁸ m/s). Its length is:

    1. 1 m
    2. 4 m
    3. 2 m
    4. 0.5 m
    Show answer

    Answer: A — 1 m

    λ = c/f = 4 m and a quarter wavelength is 1 m. The 4 m is the full wavelength.
  10. A PCM voice channel is sampled at 8 kHz and each sample is coded with 8 bits. The bit rate is:

    1. 64 kbit/s
    2. 8 kbit/s
    3. 16 kbit/s
    4. 128 kbit/s
    Show answer

    Answer: A — 64 kbit/s

    Rate = 8,000 × 8 = 64,000 bit/s. Thirty-two such channels make the 2.048 Mbit/s E1 stream.
  11. A telephone exchange receives 30 calls an hour, each lasting 4 minutes on average. The offered traffic is:

    1. 2 erlangs
    2. 120 erlangs
    3. 0.5 erlang
    4. 7.5 erlangs
    Show answer

    Answer: A — 2 erlangs

    Traffic = 30 × (4/60) = 2 erlangs, meaning two lines would be busy on average. The 120 is call-minutes, not erlangs.
  12. Light of 2 mW is launched into a fibre section with a total loss of 3 dB. The power at the far end is nearest to:

    1. 1 mW
    2. 0.5 mW
    3. 0.67 mW
    4. 1.5 mW
    Show answer

    Answer: A — 1 mW

    A 3 dB loss halves the power: 2/2 = 1 mW. Subtracting 3 mW (negative power) or 3 dB as 3 mW is meaningless.
  13. A transmission line of characteristic impedance 50 Ω is terminated in a 50 Ω load. The standing wave ratio is:

    1. 1
    2. 0
    3. 2
    4. Infinity
    Show answer

    Answer: A — 1

    A matched load gives zero reflection, so VSWR = 1. A short or open circuit gives an infinite ratio.
  14. In colour-light signalling on the railways, the aspect that means the driver must stop at the signal is:

    1. Red
    2. Yellow
    3. Green
    4. Flashing white
    Show answer

    Answer: A — Red

    Red is the stop (danger) aspect, yellow means caution and green means proceed. Red is also the fail-safe aspect, shown when a lamp or circuit fails.
  15. The wavelength of a 900 MHz signal in free space (c = 3 × 10⁸ m/s) is:

    1. 0.333 m
    2. 3 m
    3. 0.9 m
    4. 3.33 m
    Show answer

    Answer: A — 0.333 m

    λ = c ÷ f = 3 × 10⁸ ÷ 9 × 10⁸ = 0.333 m. Check: 0.333 × 900 MHz = 300 × 10⁶ m/s. Quoting 3.33 m is a factor-of-ten slip, since that is the wavelength at 90 MHz.
  16. A voltage ratio of 10 and a power ratio of 2 correspond, in decibels, to approximately:

    1. 100 dB and 6 dB
    2. 20 dB and 3 dB
    3. 10 dB and 2 dB
    4. 20 dB and 6 dB
    Show answer

    Answer: B — 20 dB and 3 dB

    Voltage ratio in dB = 20 log 10 = 20 dB, and power ratio 2 gives 10 log 2 = 3 dB. Using 10 log for the voltage ratio gives the tempting 10 dB.
  17. In a primary E1 PCM frame of 32 time slots, the number of slots available for voice channels, with slot 0 for framing and slot 16 for signalling, is:

    1. 32
    2. 31
    3. 24
    4. 30
    Show answer

    Answer: D — 30

    32 − 2 = 30 voice channels at 64 kbit/s each. The 24 channels belong to the T1 (North American) system, the tempting figure.
  18. A 25 Ω load is connected to a 50 Ω lossless line. The magnitude of the reflection coefficient and the VSWR are:

    1. 2/3 and 5
    2. 1/3 and 2
    3. 1/2 and 3
    4. 0 and 1
    Show answer

    Answer: B — 1/3 and 2

    Γ = (25 − 50) ÷ (25 + 50) = −1/3, magnitude 1/3, and VSWR = (1 + 1/3) ÷ (1 − 1/3) = 2. Check: a 50/25 or 100/50 mismatch both give VSWR 2. A zero coefficient would need a matched load.
  19. An optical fibre has a core index n₁ = 1.48 and a cladding index n₂ = 1.46. Its numerical aperture is about:

    1. 1.47
    2. 0.02
    3. 0.24
    4. 0.06
    Show answer

    Answer: C — 0.24

    NA = √(n₁² − n₂²) = √(2.1904 − 2.1316) = √0.0588 = 0.24. The 0.02 is the plain index difference, the tempting shortcut.
  20. In the absolute block system of railway working, the rule is that:

    1. Several trains may follow in a block section
    2. Only one train is allowed in a block section at a time
    3. Trains run without any signals
    4. Trains may cross at speed on single lines
    Show answer

    Answer: B — Only one train is allowed in a block section at a time

    Absolute block means the section ahead is clear of any train before another is admitted. Allowing following trains describes permissive working, the tempting contrast.
  21. A track circuit is designed on the fail-safe principle, so that a broken rail or a failed supply makes the track relay:

    1. Ignore the fault
    2. Flash a yellow aspect
    3. De-energise, so the signal shows red
    4. Stay energised, so the signal shows green
    Show answer

    Answer: C — De-energise, so the signal shows red

    The relay is normally energised when the track is clear, so a failure drops it and gives the most restrictive aspect. A green aspect on failure is the tempting unsafe error.
  22. Assertion (A): Optical fibre links are immune to electromagnetic interference.
    Reason (R): The fibre carries light rather than an electric current.
    Which one of the following is correct?

    1. Both A and R are true, and R is the correct explanation of A
    2. Both A and R are true, but R is not the correct explanation of A
    3. A is true, but R is false
    4. A is false, but R is true
    Show answer

    Answer: A — Both A and R are true, and R is the correct explanation of A

    Light in a dielectric fibre is not affected by external fields, so R explains A. Bending loss and attenuation still limit the link, which are separate issues.