Reliability, Availability and Maintenance in Numbers: Exponential and Weibull Lives, MTBF from Test Data, Series, Parallel and Standby Systems, Availability, OEE and Replacement Policies

Section 5 of the PI paper names the distribution of failure and repair times, the determination of MTBF and MTTR, reliability models, system reliability, replacement and total productive maintenance, and the earlier chapter states these without a worked case. A component with a constant hazard of 0.002/h survives 500 h with probability 0.368 (always e⁻¹ at its own MTBF); a Weibull part with β = 2 and η = 1000 h survives it with 0.779. Three units of reliability 0.95, 0.90 and 0.98 in series give 0.838; two 0.9 units in parallel give 0.99; a machine with MTBF 400 h and MTTR 8 h is available 98.04% of the time; and the cheapest replacement age for a machine costing ₹50 000 is 3 years.
Overview

Failure Distributions, Hazard Rate and MTBF from Test Data

1 min read

The reliability R(t) is the probability of survival to time t; the hazard rate h(t) = f(t)/R(t) is the instantaneous failure rate. A constant hazard λ gives the exponential law R(t) = e^(−λt) and MTBF = 1/λ: for λ = 0.002/h, MTBF = 500 h, R(500) = e⁻¹ = 0.368, and the life that 90% survive (B10) is −ln 0.9/λ = 52.7 h. The exponential law is memoryless: a part that has survived 300 h has the same chance of lasting the next 500 h, 0.368, as a new one — so only random (electronic, mid-life) failures fit it. The Weibull law R(t) = exp[−(t/η)^β] has shape β and scale η (63.2% of units fail by t = η). β < 1 is infant mortality, β = 1 exponential, β > 1 wear-out. With β = 2, η = 1000 h: R(500) = exp(−0.25) = 0.779, the mean life ηΓ(1 + 1/β) = 886.2 h, the hazard at 500 h is (β/η)(t/η)^(β−1) = 1.00 × 10⁻³ per hour (rising with time) and B10 = η(−ln 0.9)^(1/β) = 325 h. The bathtub curve joins the three regions. MTBF from a test: MTBF = total operating time / number of failures. Seven units are run; five fail at 120, 340, 410, 650 and 820 h and two survive to the end of the 1000 h test: total time = 2340 + 2 × 1000 = 5330.2875 h, so MTBF ≈ 868 h (censored survivors still add exposure time).

LawHazardMean life
ExponentialConstant λ1/λ
Weibull β < 1FallingInfant mortality
Weibull β = 1Constantη
Weibull β > 1RisingWear-out; ηΓ(1 + 1/β)

The reliability R(t) is the probability of survival to time t; the hazard rate h(t) = f(t)/R(t) is the instantaneous failure rate. A constant hazard λ gives the exponential law R(t) =…

System Reliability: Series, Parallel, k-out-of-n and Standby

1 min read

In a series system every component must work: R_s = ΠR_i, so it is always below its weakest part — three components of 0.95, 0.90 and 0.98 give 0.8379, and for exponential parts the failure rates add (λ_s = Σλ_i). In a parallel (active-redundant) system all must fail for the system to fail: R_p = 1 − Π(1 − R_i), always above the best part: two 0.9 units give 0.99. k-out-of-n systems follow the binomial sum; 2-out-of-3 of 0.9 units gives 3R² − 2R³ = 0.972 (lower than parallel, higher than a single unit). A series–parallel block (A in series with B, the pair in parallel with C; R_A = 0.9, R_B = 0.8, R_C = 0.7): R = 1 − (1 − 0.9 × 0.8)(1 − 0.7) = 0.916. With exponential lives at λ = 0.002/h and t = 500 h: two active parallel units have R = 2e^(−λt) − e^(−2λt) = 0.600 and a cold standby pair (perfect switch) R = e^(−λt)(1 + λt) = 0.736; the MTBF of the parallel pair is 1.5/λ = 750 h, of the standby pair 2/λ = 1000 h. Standby beats active redundancy because the spare does not age — as long as the switch is reliable.

ConfigurationReliabilityValue
Series 0.95, 0.90, 0.98ΠR_i0.8379
Parallel 2 × 0.91 − (1 − R)²0.99
2-out-of-3, R = 0.93R² − 2R³0.972
Cold standby, λt = 1e^(−λt)(1 + λt)0.736

In a series system every component must work: R_s = ΠR_i, so it is always below its weakest part — three components of 0.95, 0.90 and 0.98 give 0.8379, and for exponential parts the failure…

Availability, Maintainability and Total Productive Maintenance

1 min read · 1 part

Maintainability M(t) is the probability that a repair is finished within time t; for an exponential repair time with rate μ = 1/MTTR, M(t) = 1 − e^(−μt): with MTTR = 8 h, the chance of finishing within 4 h is 0.393. Inherent availability A = MTBF/(MTBF + MTTR) = 400/408 = 0.9804; improving either MTBF or MTTR raises it, which is why design for maintainability (quick-release fasteners, modular units) pays as well as design for reliability. Two identical units in parallel with independent repair give 1 − (1 − A)² = 0.99962. Overall equipment effectiveness (the TPM measure) is OEE = availability × performance × quality = 0.90 × 0.95 × 0.99 = 84.6%; a world-class target is about 85%. TPM spreads the work: autonomous maintenance by operators, planned maintenance, focused improvement of the six big losses (breakdowns, set-up, small stops, reduced speed, process defects, start-up losses), quality maintenance, training, safety and office TPM. Preventive maintenance replaces on a schedule (suited to wear-out, β > 1); predictive (condition-based) maintenance acts on vibration, oil debris or thermal measurements; neither helps a part with constant hazard, for which the best policy is to run to failure and keep spares.

MeasureFormulaValue here
Inherent availabilityMTBF/(MTBF + MTTR)0.9804
Parallel pair availability1 − (1 − A)²0.99962
OEEA × P × Q84.6%
Repair done within 4 h1 − e^(−t/MTTR)0.393

Maintainability M(t) is the probability that a repair is finished within time t; for an exponential repair time with rate μ = 1/MTTR, M(t) = 1 − e^(−μt): with MTTR = 8 h, the chance of…

Replacement and Maintenance Policies

2 min read · 2 parts

Replacement of a deteriorating machine: the best age minimises the average annual cost (purchase − salvage + cumulative running cost)/n. For a ₹50 000 machine with yearly running costs ₹6 000, 9 000, 13 000, 18 000, 24 000, 31 000 and salvage ₹30 000, 20 000, 12 000, 6 000, 3 000, 1 000, the average annual costs are ₹26,000, 22,500, 22,000, 22,500, 23,400, 25,000; the minimum is at 3 years (₹22,000/year). Replace when the next year's running cost exceeds the best average so far — the marginal rule. Group (block) replacement for items that fail suddenly (bulbs): 1000 items; failure probability in weeks 1 to 5 of life 0.05, 0.10, 0.15, 0.30, 0.40 (mean life 3.90 weeks); individual replacement costs ₹6 and group ₹1.5 per item. Individual replacement alone costs N c_i/mean life = ₹1,538 per week; replacing everything every T weeks and the failures in between costs ₹1,500, 900, 805, 844, 1,066 per week for T = 1 to 5; the cheapest is T = 3 weeks. Group replacement wins only when the group cost is well below the individual cost and failures cluster around the mean.

Year nNet cost, ₹Average cost per year, ₹
126,00026,000
245,00022,500
366,00022,000
490,00022,500
5117,00023,400
6150,00025,000
🎯 Series, parallel and availability, worked
For an exponential life R(t) = e^(−t/MTBF): MTBF 1000 h and t = 100 h give R = e^(−0.1) = 0.905. Components in series multiply, 0.95 × 0.90 = 0.855; in parallel the system fails only if all fail, 1 − (1 − 0.9)(1 − 0.9) = 0.99. Steady-state availability is MTBF/(MTBF + MTTR) = 1000/1010 = 0.990. OEE is availability × performance × quality: 0.9 × 0.95 × 0.98 = 0.838. A series system is no more reliable than its weakest component.

Replacement of a deteriorating machine: the best age minimises the average annual cost (purchase − salvage + cumulative running cost)/n. For a ₹50 000 machine with yearly running costs ₹6…

Key takeaways

  • Exponential: R = e^(−λt), MTBF = 1/λ, memoryless; Weibull β < 1, = 1, > 1 for infant mortality, random and wear-out failures.
  • MTBF from a test = total operating time (survivors included) divided by the number of failures.
  • Series multiplies reliabilities (below the weakest); parallel multiplies unreliabilities (above the best); 2-out-of-3 is 3R² − 2R³; cold standby is e^(−λt)(1 + λt).
  • Availability = MTBF/(MTBF + MTTR) and OEE = availability × performance × quality; preventive maintenance only helps wear-out failures.
  • Replace a machine at the age minimising average annual cost; group replacement suits sudden-failure items when its cost is low.

Practice questions (24)

Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.

  1. A component with a constant failure rate has survived 300 h. The probability that it survives a further 500 h, compared with a new component surviving 500 h, is:

    1. The same, because the exponential law is memoryless
    2. Zero
    3. Lower, because it has aged
    4. Higher, because it has proved itself
    Show answer

    Answer: A — The same, because the exponential law is memoryless

    R(t + s)/R(t) = e^(−λ(t+s))/e^(−λt) = e^(−λs): the past does not matter. Ageing needs a rising hazard (Weibull β > 1), and proving itself needs a falling one (β < 1).
  2. A component has a constant hazard rate of 0.002 per hour. Its reliability at 500 h (three decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.368

    R = e^(−0.002 × 500) = e⁻¹ = 0.368. A component always has R = 0.368 at its own MTBF (here 500 h) — the 50% figure is the median life, not the MTBF.
  3. Seven units are tested for 1000 h; five fail at 120, 340, 410, 650 and 820 h and two survive. The estimated MTBF in hours (nearest integer) is:

    Numerical answer — type the value.

    Show answer

    Answer: 868

    Total time on test = 2340 + 2 × 1000 = 5330.2875 h over 5 failures: 868 h. Dividing by 7 units would give 761, which is the mean time per unit, not per failure.
Show the other 21 questions
  1. For a Weibull part with shape 2 and scale 1000 h the reliability at 500 h (three decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.779

    R = exp[−(500/1000)²] = exp(−0.25) = 0.779. A constant-hazard part with the same 886 h mean would have R(500) = 0.569; the Weibull wear-out part is more reliable early and worse late.
  2. A system of three components with reliabilities 0.95, 0.90 and 0.98 in series has a reliability of:

    1. 0.9800, the best
    2. 0.9000, the weakest
    3. 0.8379, below the weakest component
    4. 0.9100, the average
    Show answer

    Answer: C — 0.8379, below the weakest component

    R = 0.95 × 0.90 × 0.98 = 0.8379. A series chain is weaker than every link, because each factor is below 1; the average or the minimum are not products.
  3. Blocks A (0.9) and B (0.8) are in series, and that pair is in parallel with block C (0.7). The system reliability (three decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.916

    Series pair = 0.9 × 0.8 = 0.72; parallel with 0.7: 1 − (1 − 0.72)(1 − 0.7) = 1 − 0.28 × 0.3 = 0.916.
  4. A cold-standby pair of identical units with λ = 0.002/h and a perfect switch is used for 500 h. The system reliability (three decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.736

    R = e^(−λt)(1 + λt) = e⁻¹ × 2 = 0.736. Active parallel redundancy gives only 0.600 because both units age together.
  5. A machine has MTBF 400 h and MTTR 8 h. Its inherent availability (four decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.9804

    A = 400/(400 + 8) = 0.9804. Using MTBF/MTTR (50) or 1 − MTTR/MTBF (0.9800) are the two common slips; the last is close but not equal.
  6. For a machine with availability 90%, performance efficiency 95% and quality rate 99%, the OEE in per cent (one decimal) is:

    Numerical answer — type the value.

    Show answer

    Answer: 84.6

    OEE = 0.90 × 0.95 × 0.99 = 0.8464 = 84.6%. It multiplies the three factors; the average (94.7%) hides the compounding of losses.
  7. For the machine with purchase price ₹50 000, running costs ₹6 000, 9 000, 13 000, 18 000, 24 000, 31 000 and salvage ₹30 000, 20 000, 12 000, 6 000, 3 000, 1 000 for years 1 to 6, the economic life in years is:

    Numerical answer — type the value.

    Show answer

    Answer: 3

    Average annual costs are ₹26,000, 22,500, 22,000, 22,500, 23,400, 25,000; the minimum is in year 3. Year 1 has the lowest running cost but a large depreciation share.
  8. Which statements about maintenance are correct?

    1. OEE is the arithmetic mean of availability, performance and quality
    2. Cold standby with a perfect switch has a higher MTBF than active parallel redundancy
    3. Availability is improved by reducing MTTR as well as by raising MTBF
    4. Preventive replacement is justified only when the hazard rate rises with age
    Show answer

    Answer: B — Cold standby with a perfect switch has a higher MTBF than active parallel redundancy; C — Availability is improved by reducing MTTR as well as by raising MTBF; D — Preventive replacement is justified only when the hazard rate rises with age

    Replacing a constant-hazard part early gains nothing; standby gives 2/λ against 1.5/λ; and A depends on both MTBF and MTTR. OEE is a product, not a mean.
  9. The "bathtub curve" of reliability shows that the failure rate over a product’s life is

    1. constant throughout
    2. high early (infant mortality), low and constant in mid-life, rising at end of life
    3. always decreasing
    4. always increasing
    Show answer

    Answer: B — high early (infant mortality), low and constant in mid-life, rising at end of life

    The bathtub curve falls (burn-in), flattens (useful life, constant rate) and rises (wear-out). A single constant or monotone rate describes only one region, not the whole life, the tempting over-simplifications.
  10. Two components with reliabilities 0.9 and 0.8 are in series. The system reliability is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.72

    Series: R = 0.9 × 0.8 = 0.72, since both must work. Averaging (0.85) ignores that failure of either fails the system.
  11. A redundant (parallel) pair of units has reliabilities 0.7 and 0.6. The combined reliability is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.88

    Parallel: R = 1 − (1 − 0.7)(1 − 0.6) = 1 − 0.12 = 0.88, higher than either unit. Multiplying 0.7 × 0.6 = 0.42 gives the series value, the common mix-up.
  12. A machine has a mean time between failures of 500 h and a mean time to repair of 50 h. Its availability A = MTBF/(MTBF + MTTR), to three decimals, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.909

    A = 500/(500 + 50) = 500/550 = 0.909. Using MTTR/(MTBF + MTTR) = 0.091 gives the downtime fraction, not availability.
  13. Group (preventive) replacement of many identical low-cost items is preferred over individual replacement when

    1. failures rise with age and the fixed cost per replacement visit is high
    2. each item is very expensive
    3. replacement is free
    4. items never fail
    Show answer

    Answer: A — failures rise with age and the fixed cost per replacement visit is high

    Group replacement pays off for cheap items with age-rising failure and high per-visit (setup) cost, as replacing all at once saves repeated call-outs. Very expensive items favour individual replacement, the tempting opposite.
  14. Three identical components, each of reliability 0.9, are in series. The system reliability, to three decimals, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.729

    R = 0.9³ = 0.729. Multiplying 0.9 × 3 = 2.7 is dimensionally impossible for a probability. Substituting the answer back into the relation confirms it.
  15. A component’s life follows a Weibull reliability R(t) = e^(−(t/η)^β) with η = 200 h and β = 2. Its reliability at t = 100 h, to three decimals, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.779

    R = e^(−(100/200)²) = e^(−0.25) = 0.779. Forgetting the exponent β (using t/η = 0.5 → e^(−0.5) = 0.607) misapplies the Weibull shape.
  16. Which statements about preventive and breakdown (corrective) maintenance are correct?

    1. Over-maintenance can raise total cost
    2. Breakdown maintenance acts only after a failure occurs
    3. Preventive maintenance is scheduled before failure to reduce unplanned downtime
    4. Preventive maintenance guarantees zero failures
    Show answer

    Answer: A — Over-maintenance can raise total cost; B — Breakdown maintenance acts only after a failure occurs; C — Preventive maintenance is scheduled before failure to reduce unplanned downtime

    Preventive work is scheduled, breakdown work is reactive, and too much PM wastes money. No schedule can guarantee zero random failures, so the last claim is the trap.
  17. A machine with availability 0.909 is scheduled for 600 h in a month. Its expected uptime, in h (one decimal), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 545.4

    Uptime = availability × scheduled time = 0.909 × 600 = 545.4 h. Multiplying by the downtime fraction (0.091 × 600 = 54.6) gives the repair time instead.
  18. For a system to reach reliability 0.99 using identical parallel units of reliability 0.9, two units give R = 1 − (1 − 0.9)². This value is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.99

    R = 1 − 0.1² = 1 − 0.01 = 0.99, so two parallel 0.9 units reach the target. Multiplying 0.9 × 0.9 = 0.81 gives the series value, far below the goal.
  19. A system has one component of reliability 0.95 in series with a parallel pair each of reliability 0.8. The overall reliability, to three decimals, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.912

    Parallel pair: 1 − (0.2)(0.2) = 0.96; series with 0.95: 0.95 × 0.96 = 0.912. Treating all three in series (0.95 × 0.8 × 0.8 = 0.608) ignores the redundancy.
  20. For a Weibull life with scale η = 200 h and shape β = 2, the mean time to failure MTTF = η·Γ(1 + 1/β), with Γ(1.5) = 0.8862, in h (one decimal), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 177.2

    MTTF = 200 × Γ(1.5) = 200 × 0.8862 = 177.2 h. Taking MTTF = η = 200 (true only for β = 1, the exponential case) ignores the shape factor.
  21. A machine is scheduled for 100 h but is under repair for 5 h and idle (no work) for 10 h. Its availability (uptime/scheduled time, counting idle as available) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.95

    Availability counts only repair (unplanned downtime): A = (100 − 5)/100 = 0.95; idle time is available capacity, not a reliability loss. Subtracting the idle 10 h as well (0.85) confuses utilisation with availability.