Radiation Laws, View Factors and Networks, Boiling and Condensation
View Factors, the Radiation Network and Shields
The view factor F_ij is the fraction of the radiation leaving surface i that strikes surface j directly. Three rules do most of the work: reciprocity A_i F_ij = A_j F_ji; summation Σ_j F_ij = 1 over all surfaces of an enclosure, including i itself; and F_ii = 0 for a flat or convex surface, which cannot see itself. A small sphere of radius 0.1 m inside a concentric one of 0.3 m sees only the outer sphere (F₁₂ = 1), so by reciprocity F₂₁ = A₁/A₂ = (0.1/0.3)² = 0.111, and the outer sphere's remaining 0.889 is F₂₂, the concave surface seeing itself. For two surfaces in an enclosure the net exchange is a series circuit: Q₁₂ = σ(T₁⁴ − T₂⁴) / [ (1−ε₁)/(ε₁A₁) + 1/(A₁F₁₂) + (1−ε₂)/(ε₂A₂) ], each term a resistance — two surface resistances and one space resistance. Black surfaces have zero surface resistance and the formula collapses to σ A₁ F₁₂ (T₁⁴ − T₂⁴).
Parallel plates and shields. For large parallel plates F₁₂ = 1 and A₁ = A₂, giving q = σ(T₁⁴ − T₂⁴) / (1/ε₁ + 1/ε₂ − 1). Between 600 K and 300 K with ε = 0.8 on both: black plates would exchange 6890 W/m², grey plates 4593 W/m². Insert a thin radiation shield of the same emissivity between them: it adds two surface resistances and one space resistance, and with equal emissivities the exchange is exactly halved to 2297 W/m²; n identical shields leave 1/(n + 1) of the original. A shield of low emissivity does far better, which is why vacuum flasks and cryogenic insulation use polished multilayer foils. Treat the radiosity J (everything leaving a surface, emitted plus reflected) as the node voltage: for a surface in a network, J = E_b − (1−ε)/(εA) · Q.
| Result | Formula | When |
|---|---|---|
| Reciprocity | A_i F_ij = A_j F_ji | always |
| Enclosure summation | Σ_j F_ij = 1 | closed set of surfaces |
| Large parallel plates | q = σ(T₁⁴−T₂⁴)/(1/ε₁+1/ε₂−1) | F₁₂ = 1, A₁ = A₂ |
| n shields, equal ε | q_n = q₀ / (n+1) | thin, same emissivity as plates |
The view factor F_ij is the fraction of the radiation leaving surface i that strikes surface j directly. Three rules do most of the work: reciprocity A_i F_ij = A_j F_ji; summation Σ_j F_ij…
Boiling: The Curve, the Peak and the Burnout
In pool boiling a heated surface sits in a stagnant liquid at saturation. Plot heat flux against the excess temperature ΔT_e = T_wall − T_sat (Nukiyama curve) and four regimes appear. Natural convection at small ΔT_e (below roughly 5 K for water at 1 atm), where vapour forms only at the free surface. Nucleate boiling (roughly 5–30 K) — bubbles form at wall cavities, grow and detach, stirring the layer; the coefficients are very large and the flux rises steeply, q ∝ ΔT_e³ in the Rohsenow correlation. The critical heat flux (peak) is where vapour columns crowd out liquid from the wall; Zuber's relation gives q_max ≈ 0.131 ρ_v^½ h_fg [σ g (ρ_l − ρ_v)]^¼, about 1.11 MW/m² for water at 1 atm (using h_fg = 2257 kJ/kg, ρ_v = 0.598, ρ_l = 958, σ = 0.0589 N/m). Beyond it lies transition boiling — an unstable mix of wetting and vapour blanket in which the flux falls as ΔT_e rises — down to the Leidenfrost point (minimum flux), then stable film boiling, where a continuous vapour film insulates the surface and radiation adds to it.
The point of the curve for an engineer is burnout. Under a heat-flux-controlled surface (an electrical heater, a nuclear fuel rod) a small rise above q_max cannot be carried by nucleate boiling, so the wall temperature jumps along a vertical line to the film-boiling branch, often above the melting point: the burnout (or departure from nucleate boiling). Under a temperature-controlled surface (condensing steam on the other side) the transition branch can be traced. Hence designs keep a margin to the critical heat flux (a DNB ratio above 1 in reactors). Flow boiling in tubes adds quality, void fraction and dry-out, but the same logic holds. The coefficient in nucleate boiling grows with pressure and with surface roughness; it hardly depends on flow velocity.
- Natural convectionBelow roughly 5 K for water
- Nucleate boilingRoughly 5–30 K; q ∝ ΔT_e³
- Critical heat fluxThe peak
- Transition boiling
- Leidenfrost pointMinimum flux
- Film boiling

In pool boiling a heated surface sits in a stagnant liquid at saturation. Plot heat flux against the excess temperature ΔT_e = T_wall − T_sat (Nukiyama curve) and four regimes appear.…
Condensation: Film, Dropwise and the Nusselt Result
Vapour at saturation touching a wall below T_sat condenses. If the liquid wets the wall it forms a continuous film whose thickness grows downward, and the film is the resistance: film condensation. If it does not wet, discrete drops form, grow and roll off, repeatedly exposing bare metal: dropwise condensation, with coefficients 5–10 times larger but hard to sustain on ordinary surfaces, so exchangers are designed for film condensation. Nusselt's analysis of a laminar film on a vertical plate of height L gives the mean coefficient h = 0.943 [ ρ_l (ρ_l − ρ_v) g h′_fg k_l³ / (μ_l L (T_sat − T_w)) ]^¼, with h′_fg = h_fg + 0.68 c_p ΔT correcting for subcooling and liquid properties at the film temperature. The exponents are the useful result: h ∝ L^(−1/4) (ΔT)^(−1/4) — a taller plate or a bigger temperature difference thickens the film and lowers the average coefficient. For steam at 100 °C on a 0.5 m plate at 90 °C (film-temperature properties near 95 °C) this evaluates to about 7.64 kW/m²·K, a flux of 76.4 kW/m² and 0.0168 kg/s of condensate per metre of width.
Two consequences matter in exchanger design. A horizontal tube beats a vertical one: the film on a horizontal tube of diameter D is governed by D rather than the much longer L, and the coefficient is h = 0.725 [ … / (μ_l D ΔT) ]^¼ — for the same data on a 25 mm tube it is about 12.4 kW/m²·K against 7.6 for the plate. Condensers therefore stack horizontal tubes, noting that the condensate drips on the tubes below and thickens their film. And the film's Reynolds number Re = 4Γ/μ_l (Γ = condensate per unit width; here 227) sorts laminar (below about 30, smooth), wavy-laminar (about 30–1800, with a modest rise in h above Nusselt) and turbulent (above about 1800, where h rises with length). Non-condensable gases such as air are the great enemy: they collect at the interface and a few per cent by mass can cut the coefficient several-fold, which is why condensers carry air-extraction equipment.
- Liquid wets the wall
- The film is the resistance
- Exchangers are designed for it
- Liquid does not wet
- Drops roll off, baring metal
- 5–10 times larger, hard to sustain
Vapour at saturation touching a wall below T_sat condenses. If the liquid wets the wall it forms a continuous film whose thickness grows downward, and the film is the resistance: film…
Key takeaways
- E_b = σT⁴ (T absolute, σ = 5.67×10⁻⁸); λ_max T = 2898 μm·K; real surface E = εσT⁴; α + ρ + τ = 1 and Kirchhoff α = ε for diffuse-grey surfaces.
- View factors: A_iF_ij = A_jF_ji, ΣF_ij = 1, F_ii = 0 for flat or convex surfaces; inner sphere in an enclosing sphere has F₁₂ = 1 and F₂₁ = A₁/A₂.
- Radiation network: surface resistance (1−ε)/(εA) plus space resistance 1/(AF); parallel plates q = σΔ(T⁴)/(1/ε₁+1/ε₂−1); n equal-ε shields divide the exchange by n+1.
- Pool boiling: natural convection, nucleate, transition, film; the peak (critical) flux, about 1.1 MW/m² for water at 1 atm, is the design limit because a flux-controlled surface burns out beyond it.
- Film condensation: h ∝ (L ΔT)^(−1/4) on a vertical plate; dropwise is 5–10 times better but unreliable; a horizontal tube beats a vertical one; non-condensable gases wreck the coefficient.
Practice questions (24)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
By what factor does the emissive power of a black surface change when its absolute temperature doubles?
Show answer
Answer: C — 16
E_b = σT⁴, so doubling the absolute temperature multiplies E_b by 2⁴ = 16. The tempting answer 4 comes from squaring instead of raising to the fourth power.A black surface is at 1000 K. Find its emissive power in kW/m² (σ = 5.67 × 10⁻⁸ W/m²K⁴; nearest integer).
Numerical answer — type the value.
Show answer
Answer: 57
E_b = σT⁴ = 5.67×10⁻⁸ × (1000)⁴ = 5.67×10⁴ W/m² = 56.7 kW/m². The usual slip is to forget the fourth power of the temperature or to leave the answer in W/m².By Wien's displacement law, a surface at 300 K radiates with its spectral peak at about:
Show answer
Answer: D — 9.7 μm
λ_max = 2898 μm·K / 300 K = 9.7 μm, in the infrared. 0.5 μm is the Sun (about 5800 K), which is why solar and room-temperature radiation can be treated as different bands.
Show the other 21 questions
For an opaque surface at the same temperature as its source of radiation, Kirchhoff's law states that:
Show answer
Answer: D — absorptivity equals emissivity
Kirchhoff: α = ε. For opaque bodies α + ρ = 1 so ρ = 1 − ε, and a good absorber is an equally good emitter.A small sphere of radius r₁ sits inside a concentric sphere of radius r₂ = 3 r₁. The view factor F₂₁ from the outer to the inner surface is:
Show answer
Answer: A — 0.111
F₁₂ = 1 (the inner sphere sees only the outer). By reciprocity A₁F₁₂ = A₂F₂₁, so F₂₁ = (r₁/r₂)² = 1/9 = 0.111. The 0.333 option forgets that area goes as radius squared.Two large parallel grey plates exchange radiation. A single thin shield with the same emissivity as the plates is inserted between them. The net exchange becomes:
Show answer
Answer: C — one half
The shield doubles the total resistance (two gaps in series, each of the same resistance as the original, joined through surfaces of the same emissivity), so the flux is halved; n shields give 1/(n + 1).Two large parallel plates at 600 K and 300 K, both with emissivity 0.8, exchange per unit area nearest to (σ = 5.67 × 10⁻⁸):
Show answer
Answer: A — 4593 W/m²
q = σ(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1) = 6890 / 1.5 = 4593 W/m². The 6890 figure is the black-plate value, and 2297 is with a shield.A heat-flux-controlled heater is raised slightly above the critical heat flux of pool boiling. The wall temperature:
Show answer
Answer: A — jumps sharply to the film-boiling branch (burnout)
Beyond q_max nucleate boiling cannot remove the imposed flux, and since flux is held fixed the only stable state is the film-boiling branch at a much higher ΔT_e — often above the metal's melting point, hence "burnout".In Nusselt film condensation on a vertical plate, the average heat-transfer coefficient varies with the plate height L and temperature difference ΔT as:
Show answer
Answer: A — h ∝ L^(−1/4) ΔT^(−1/4)
A longer plate or larger ΔT produces a thicker liquid film, and the film is the conduction resistance, so the average coefficient falls with the quarter power of both. That is why short, many-tube arrangements are preferred.A black surface is at 500 K (σ = 5.67×10⁻⁸ W/m²K⁴). Its emissive power σT⁴, in W/m² to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 3544
E_b = 5.67×10⁻⁸ × 500⁴ = 5.67×10⁻⁸ × 6.25×10¹⁰ = 3544 W/m². Using T = 227 °C would give a far smaller number. Substituting the answer back into the relation confirms it.By Wien’s displacement law λ_max T = 2898 μm·K, a black body at 5800 K (like the Sun’s surface) has its spectral peak at, in μm to two decimal places, ____.
Numerical answer — type the value.
Show answer
Answer: 0.5
λ_max = 2898/5800 = 0.50 μm, in the visible (green) range. Using T in °C would put the peak at a much longer wavelength.Two surfaces have areas A₁ = 2 m² and A₂ = 4 m², and the view factor F₁₂ = 0.5. By reciprocity the view factor F₂₁ is ____.
Numerical answer — type the value.
Show answer
Answer: 0.25
A₁F₁₂ = A₂F₂₁ gives F₂₁ = 2 × 0.5/4 = 0.25. Taking F₂₁ = F₁₂ = 0.5 ignores the different areas. Substituting the answer back into the relation confirms it.An opaque surface (transmissivity zero) has an absorptivity of 0.7. Its reflectivity is ____.
Numerical answer — type the value.
Show answer
Answer: 0.3
α + ρ + τ = 1 with τ = 0 gives ρ = 1 − 0.7 = 0.3. Answering 0.7 repeats the absorptivity. Substituting the answer back into the relation confirms it.In pool boiling as the wall superheat is raised, the correct order of regimes is:
Show answer
Answer: B — natural convection, nucleate boiling, transition boiling, film boiling
The heat flux rises through nucleate boiling to the critical heat flux, falls through the unstable transition region, and then rises again in stable film boiling. The reversed list runs from high to low superheat.Two parallel black surfaces of area 1 m² at 600 K and 300 K exchange radiation (view factor 1). The net exchange σA(T₁⁴ − T₂⁴), in W to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 6889
Q = 5.67×10⁻⁸ × (600⁴ − 300⁴) = 5.67×10⁻⁸ × 1.215×10¹¹ = 6889 W. Using (T₁ − T₂)⁴ would give only 459 W. Substituting the answer back into the relation confirms it.In an enclosure of three surfaces, surface 1 has view factors F₁₂ = 0.3 and F₁₃ = 0.5. The self-view factor F₁₁ is ____.
Numerical answer — type the value.
Show answer
Answer: 0.2
The summation rule gives F₁₁ + F₁₂ + F₁₃ = 1, so F₁₁ = 1 − 0.8 = 0.2 (surface 1 sees itself, so it is concave). Answering 0 assumes a flat or convex surface.The radiation heat flux between two black parallel plates is 900 W/m². After inserting two thin black radiation shields between them, the flux becomes, in W/m², ____.
Numerical answer — type the value.
Show answer
Answer: 300
With n shields of equal emissivity the flux falls to 1/(n + 1) of the unshielded value: 900/3 = 300 W/m². A single shield would give 450 W/m².In Nusselt film condensation on a vertical plate the average heat-transfer coefficient varies as (ΔT)^(−1/4). If the wall-to-saturation temperature difference is doubled, h changes by a factor of, to three decimal places, ____.
Numerical answer — type the value.
Show answer
Answer: 0.841
h ∝ ΔT^(−0.25), so the factor is 2^(−0.25) = 0.841 (h falls by about 16 %). Answering 0.5 treats h as inversely proportional to ΔT.A surface (ε = 0.8) at 400 K radiates to surroundings at 300 K. The linearised radiation coefficient h_r = εσ(T_s + T_∞)(T_s² + T_∞²), in W/m²K to two decimal places, is ____.
Numerical answer — type the value.
Show answer
Answer: 7.94
h_r = 0.8 × 5.67×10⁻⁸ × 700 × (160 000 + 90 000) = 7.94 W/m²K, so q = h_r(T_s − T_∞) = 794 W/m². Using the temperatures in °C breaks the T⁴ law.Zuber’s critical heat flux q″_max = 0.131 h_fg ρ_v^(1/2)[σ g (ρ_l − ρ_v)]^(1/4) is applied to water at 100 °C: h_fg = 2.257×10⁶ J/kg, ρ_v = 0.598 kg/m³, ρ_l = 957.9 kg/m³, σ = 0.0589 N/m. The value, in MW/m² to two decimal places, is ____.
Numerical answer — type the value.
Show answer
Answer: 1.11
The bracket is 0.0589 × 9.81 × 957.3 = 553, whose fourth root is 4.85, and √0.598 = 0.773, so q″_max = 0.131 × 2.257×10⁶ × 0.773 × 4.85 = 1.11×10⁶ W/m². Using ρ_l alone in the bracket would overstate it.Two large parallel grey plates at 600 K (ε = 0.8) and 300 K (ε = 0.6) exchange radiation. The net flux q = σ(T₁⁴ − T₂⁴)/(1/ε₁ + 1/ε₂ − 1), in W/m² to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 3594
The denominator is 1.25 + 1.667 − 1 = 1.917 and σ(T₁⁴ − T₂⁴) = 6889, so q = 3594 W/m². Using ε₁ε₂ = 0.48 as a multiplier gives 3307, which is not the series-resistance form.A small body of area 0.2 m² and emissivity 0.5 at 800 K sits in a very large enclosure at 300 K. The net radiation loss εσA(T₁⁴ − T₂⁴), in W to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 2277
Q = 0.5 × 5.67×10⁻⁸ × 0.2 × (800⁴ − 300⁴) = 5.67×10⁻⁹ × 4.015×10¹¹ = 2277 W. Dropping ε (treating the body as black) would double the loss to 4553 W.Saturated steam at 100 °C condenses on a vertical plate 0.5 m high held 10 K below saturation. With ρ_l = 958 kg/m³, ρ_v = 0.6 kg/m³, h_fg = 2.257×10⁶ J/kg, k = 0.68 W/m·K and μ = 2.82×10⁻⁴ Pa·s, the Nusselt average coefficient h = 0.943[ρ_l(ρ_l − ρ_v) g h_fg k³/(μ L ΔT)]^(1/4), in W/m²K to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 7736
The bracket is 958 × 957.4 × 9.81 × 2.257×10⁶ × 0.314/(2.82×10⁻⁴ × 0.5 × 10) = 4.53×10¹⁵, whose fourth root is 8203, so h = 0.943 × 8203 = 7736 W/m²K. Omitting the 0.943 factor would give 8203 W/m²K.Two large parallel plates of emissivity 0.8 at 600 K and 300 K have a thin shield of emissivity 0.1 (both sides) placed between them. The net flux q = σ(T₁⁴ − T₂⁴)/[(1/ε₁ + 1/ε_s − 1) + (1/ε_s + 1/ε₂ − 1)], in W/m² to the nearest integer, is ____.
Numerical answer — type the value.
Show answer
Answer: 336
Each gap has resistance 1/0.8 + 1/0.1 − 1 = 10.25, so the total is 20.5 and q = 6889/20.5 = 336 W/m². Without the shield the flux would be 6889/1.5 = 4593 W/m², so the low-emissivity shield cuts it by 93 %.