Mass-Transfer Operations at Working Depth: Liquid–Liquid Extraction, Leaching, Drying, Humidification and Cooling Towers, Adsorption and Membrane Separations
Drying: Equilibrium Moisture and the Drying-Rate Curve
Moisture on a dry basis is X = kg water/kg dry solid. The equilibrium moisture X* depends on the air humidity; free moisture is X − X*; bound moisture is held below the vapour pressure of pure water, unbound above it. The drying-rate curve has a warming-up period, a constant-rate period (surface wetness, rate N_c set by external heat and mass transfer and independent of the solid) down to the critical moisture X_c, and a falling-rate period controlled by internal movement of moisture (diffusion, capillarity). The time in the constant-rate period is t_c = (W_s/AN_c)(X₁ − X_c), and in the falling-rate period, if the rate is proportional to the free moisture, t_f = (W_s/AN_c)X_c ln(X_c/X₂) (taking X* = 0). Example: W_s = 100 kg dry solid, A = 10 m², N_c = 1.5 kg/m²h, X₁ = 0.30, X_c = 0.15, X₂ = 0.05: t_c = 6.667 × 0.15 = 1.000 h, t_f = 6.667 × 0.15 × ln 3 = 1.099 h, total 2.099 h.
Dryer types. Tray and tunnel dryers for batch or semi-continuous solids; rotary dryers for granular solids (parallel or counter-current, with lifting flights); fluid-bed dryers for particles that fluidise; spray dryers for solutions and slurries (seconds of contact, a powder product, high gas rate); drum dryers for pastes; freeze dryers for heat-sensitive products (sublimation under vacuum). The constant-rate rate is raised by hotter, faster, drier air; the falling-rate time by smaller particles or thinner beds, because it depends on internal diffusion length squared. A dryer is an adiabatic humidifier for the air: the exit air approaches the wet-bulb temperature during the constant-rate period.
| Quantity | Value |
|---|---|
| Constant-rate time t_c | 1.000 h |
| Falling-rate time t_f | 1.099 h |
| Total drying time | 2.099 h |
- Tray and tunnelBatch or semi-continuous solids
- RotaryGranular solids
- Fluid-bedParticles that fluidise
- SpraySolutions and slurries
- DrumPastes
- FreezeHeat-sensitive products
- Warming-up period
- Constant-rate periodSurface wet; rate set externally
- Critical moisture X_c
- Falling-rate periodInternal moisture movement controls

Moisture on a dry basis is X = kg water/kg dry solid. The equilibrium moisture X* depends on the air humidity; free moisture is X − X*; bound moisture is held below the vapour pressure of…
Humidification, Psychrometry and Cooling Towers
Humidity ω = 0.622 p_v/(P − p_v) kg water/kg dry air; relative humidity φ = p_v/p_sat; humid heat c_s = 1.005 + 1.88ω kJ/kg·K; enthalpy h = 1.005T + ω(2501 + 1.88T) kJ/kg dry air. Example: air at 30 °C (p_sat = 4.246 kPa), 60% RH, 101.325 kPa: p_v = 2.548 kPa, ω = 0.01604 kg/kg, the dew point is the temperature at which p_sat = p_v, 21.4 °C, c_s = 1.035 kJ/kg·K and h = 71.2 kJ/kg. Along the adiabatic saturation line the wet-bulb temperature T_w satisfies h(T_w, ω_s) = const; for the air–water system the wet-bulb and adiabatic-saturation temperatures nearly coincide because the Lewis number h/(k_yc_s) ≈ 1; for other vapours they differ. Dehumidification is by cooling below the dew point (condensation) or by adsorbents.
Cooling towers cool water by evaporation into air and are limited by the wet-bulb temperature: range = hot minus cold water temperature, approach = cold water minus wet-bulb. Water at 100 kg/s cooled from 40 °C to 30 °C releases 100 × 4.18 × 10 = 4180 kW, of which the latent heat of evaporation (2400 kJ/kg) removes most; the evaporation loss is about 4180/2400 = 1.74 kg/s (1.74% of the circulation), so make-up of about 1.7% plus drift and blowdown is needed. The Merkel equation gives the height from ∫dh/(h* − h) with the enthalpy driving force; tower fill height Z = H_OG × N_OG. Natural-draught, induced-draught and forced-draught designs differ in fan power and recirculation risk. The minimum air rate corresponds to the exit air reaching the saturation curve at the hot-water temperature.
| Quantity | Value |
|---|---|
| Humidity, 30 °C, 60% RH | 0.01604 kg/kg |
| Dew point | 21.4 °C |
| Humid enthalpy | 71.2 kJ/kg |
| Cooling-tower evaporation, 100 kg/s, range 10 K | 1.74 kg/s |
Humidity ω = 0.622 p_v/(P − p_v) kg water/kg dry air; relative humidity φ = p_v/p_sat; humid heat c_s = 1.005 + 1.88ω kJ/kg·K; enthalpy h = 1.005T + ω(2501 + 1.88T) kJ/kg dry air. Example…
Adsorption and Membrane Separations
Adsorption isotherms. Langmuir: q = q_mKp/(1 + Kp) (monolayer, saturating at q_m); Freundlich q = KC^(1/n) (empirical); BET for multilayer and surface area. For q_m = 0.2 kg/kg, K = 0.05 kPa⁻¹ and p = 10 kPa: q = 0.2 × 0.5/1.5 = 0.0667 kg/kg. In a fixed bed the concentration front (mass-transfer zone) moves through the column; breakthrough occurs when the front reaches the exit. The stoichiometric (ideal) breakthrough time is t* = ρ_bq₀L/(C₀v): ρ_b = 500 kg/m³, q₀ = 0.15 kg/kg, C₀ = 0.01 kg/m³, v = 0.3 m/s, L = 0.5 m gives t* = 12500 s = 3.47 h; the real breakthrough comes earlier by the length of the unused bed (LUB). Regeneration is by temperature swing (TSA) or pressure swing (PSA); activated carbon, zeolites, silica gel and alumina are the usual adsorbents, and adsorption is exothermic.
Membranes. Reverse osmosis needs Δp > Δπ, with water flux J_w = A(Δp − Δπ) and salt rejection R = 1 − C_p/C_f. The van't Hoff osmotic pressure is π = iCRT: seawater of 35 g/L NaCl, C = 35/58.44 = 0.599 mol/L, i = 2, T = 298 K gives π = 29.7 bar. With A = 3×10⁻¹² m/s·Pa and Δp = 60 bar: J_w = 3×10⁻¹²(60×10⁵ − 2.97e+06) = 9.09e-06 m/s = 32.7 L/m²h; permeate of 0.35 g/L means R = 99%. Concentration polarisation raises the wall concentration C_m/C_b = exp(J/k) = exp(2×10⁻⁵/5×10⁻⁵) = 1.49, which lowers the effective driving force. Process families: microfiltration and ultrafiltration (pore sieving, Δp of a few bar), nanofiltration and RO (solution–diffusion), gas separation (permeability ratio α* = P_A/P_B, flux ∝ Δp), pervaporation, dialysis and electrodialysis.
| Quantity | Value |
|---|---|
| Langmuir loading, 10 kPa | 0.0667 kg/kg |
| Stoichiometric breakthrough time | 3.47 h |
| Seawater osmotic pressure, 35 g/L NaCl | 29.7 bar |
| RO water flux at 60 bar | 32.7 L/m²h |
| Polarisation modulus exp(J/k) | 1.49 |
Adsorption isotherms. Langmuir: q = q_mKp/(1 + Kp) (monolayer, saturating at q_m); Freundlich q = KC^(1/n) (empirical); BET for multilayer and surface area. For q_m = 0.2 kg/kg, K = 0.05…
Key takeaways
- Dilute extraction: single-stage X = FX_F/(F + KS); counter-current unextracted fraction (E − 1)/(E^(N+1) − 1); cross-current [1/(1 + E_i)]^N is worse.
- Leaching with constant underflow solution is solved stage by stage; internal diffusion usually controls; recovery rises with counter-current stages.
- Drying: t_c = (W_s/AN_c)(X₁ − X_c); t_f = (W_s/AN_c)X_c ln(X_c/X₂); the constant rate is set by external conditions.
- ω = 0.622p_v/(P − p_v); cooling towers approach the wet-bulb temperature; evaporation loss ≈ Q/λ ≈ 1.7% of circulation for a 10 K range.
- Langmuir q = q_mKp/(1 + Kp); breakthrough time t* = ρ_bq₀L/(C₀v); RO flux A(Δp − Δπ) with π = iCRT, and polarisation exp(J/k).
Practice questions (24)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
A feed of 100 kg carrier at X_F = 0.10 kg solute/kg carrier is contacted in one ideal stage with 50 kg pure solvent (Y = 2X). The raffinate concentration X (three decimals) is:
Numerical answer — type the value.
Show answer
Answer: 0.050
Balance: 100(0.10 − X) = 50(2X) → 10 = 200X → X = 0.050; recovery 50%.For the same system, three counter-current ideal stages (extraction factor E = 1) leave an unextracted fraction of the solute of, in percent (nearest integer):
Numerical answer — type the value.
Show answer
Answer: 25
For E = 1 the fraction is 1/(N + 1) = 1/4 = 25%, better than the 42.2% of cross-current contact.In a dryer, W_s = 100 kg dry solid, A = 10 m², N_c = 1.5 kg/m²h; the solid dries from X₁ = 0.30 to X_c = 0.15. The constant-rate time in h (two decimals) is:
Numerical answer — type the value.
Show answer
Answer: 1.00
t_c = (W_s/AN_c)(X₁ − X_c) = (100/15)(0.15) = 1.00 h.
Show the other 21 questions
Continuing, the falling-rate time to dry from X_c = 0.15 to X₂ = 0.05 (rate proportional to free moisture, X* = 0) in h (three decimals) is:
Numerical answer — type the value.
Show answer
Answer: 1.099
t_f = (W_s/AN_c)X_c ln(X_c/X₂) = 6.667 × 0.15 × ln 3 = 1.099 h.Air at 30 °C (saturation pressure 4.246 kPa), 60% relative humidity, at 101.325 kPa has an absolute humidity in kg water/kg dry air (five decimals) of:
Numerical answer — type the value.
Show answer
Answer: 0.01604
p_v = 0.6 × 4.246 = 2.548 kPa; ω = 0.622 × 2.548/(101.325 − 2.548) = 0.01604.The lowest temperature to which a cooling tower can cool water is limited by the:
Show answer
Answer: A — wet-bulb temperature of the entering air
Evaporative cooling can approach but not pass the wet-bulb temperature of the ambient air; the difference is the approach, typically 3–5 K.A Langmuir adsorbent has q_m = 0.2 kg/kg and K = 0.05 kPa⁻¹. The equilibrium loading at 10 kPa in kg/kg (four decimals) is:
Numerical answer — type the value.
Show answer
Answer: 0.0667
q = q_mKp/(1 + Kp) = 0.2 × 0.5/1.5 = 0.0667 kg/kg.Seawater containing 35 g/L NaCl (M = 58.44, fully dissociated) at 298.15 K has a van't Hoff osmotic pressure in bar (one decimal) of:
Numerical answer — type the value.
Show answer
Answer: 29.7
C = 35/58.44 = 0.599 mol/L; π = iCRT = 2 × 0.599 × 0.08314 × 298.15 = 29.7 bar.Which statements about drying and membranes are correct?
Show answer
Answer: A — Reverse osmosis needs an applied pressure above the osmotic pressure; D — In the constant-rate period the drying rate is set by external heat and mass transfer
The constant rate is an external-conditions rate; RO needs Δp > Δπ. Polarisation raises wall concentration and so lowers the net driving force, and the falling-rate time grows with particle size.At equilibrium a solute has 0.3 kg/kg in the extract phase and 0.1 kg/kg in the raffinate phase. Its distribution coefficient (extract/raffinate) is ____.
Numerical answer — type the value.
Show answer
Answer: 3
K = y/x = 0.3/0.1 = 3, so the solvent favours the solute. Inverting it (0.33) would suggest a poor solvent; the definition puts the extract phase on top.For a solvent to be usable in liquid–liquid extraction, its selectivity (separation factor) for the solute over the carrier must be
Show answer
Answer: A — greater than 1
Selectivity is the extraction analogue of relative volatility; at β = 1 the solute and carrier distribute alike and no separation occurs. Values below 1 would mean the solvent prefers the carrier.The equilibrium moisture content of a solid is the moisture that
Show answer
Answer: B — cannot be removed by air of the given humidity and temperature, however long the exposure
X* depends on the air's relative humidity; only bone-dry air could take the solid to zero. Moisture removed in the constant-rate period is unbound surface water, a different quantity.The wet-bulb temperature of air equals its dry-bulb temperature when
Show answer
Answer: A — the air is saturated (100 % relative humidity)
With saturated air no water evaporates from the wick, so there is no evaporative cooling. Completely dry air gives the LARGEST wet-bulb depression, the reverse case.Air has a water-vapour partial pressure of 2 kPa where the saturation pressure is 4 kPa. Its relative humidity, in per cent, is ____.
Numerical answer — type the value.
Show answer
Answer: 50
RH = p_v/p_sat × 100 = 50 %. Percentage saturation (based on humidity ratios) is slightly different; dividing p_v by total pressure gives the mole fraction, not RH.A membrane module of 2 m² produces 50 L/h of permeate. Its flux, in L/m²·h, is ____.
Numerical answer — type the value.
Show answer
Answer: 25
J = Q/A = 50/2 = 25 L/m²h (LMH). Multiplying gives 100, which would mean a larger module produces less per unit area.A wet solid contains 20 % water on a wet basis. Its moisture content on a dry basis, in kg water/kg dry solid (two decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 0.25
X = w/(1 − w) = 0.2/0.8 = 0.25. Quoting 0.20 keeps the wet basis; drying calculations use dry-basis X because the dry-solid mass stays constant.A feed of 100 kg carrier is extracted in two ideal cross-current stages, each with 25 kg of fresh solvent; the distribution coefficient (kg/kg basis) is 2 and the phases are immiscible. The fraction of solute left in the raffinate (four decimals) is ____.
Numerical answer — type the value.
Show answer
Answer: 0.4444
Each stage has extraction factor E = KS/B = 2 × 25/100 = 0.5 and leaves 1/(1 + E) = 2/3, so two stages leave (2/3)² = 0.4444. One stage with all 50 kg would leave 0.5; splitting the solvent does better, which is the point of cross-current contact.Air at 101.325 kPa has a water-vapour partial pressure of 2 kPa. Its absolute humidity, in kg water/kg dry air (four decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 0.0125
Y = 0.622 p_v/(P − p_v) = 0.622 × 2/99.325 = 0.0125. Dividing by P instead of P − p_v gives 0.0123; the basis is kg of DRY air.A cooling tower cools water from 40 °C to 30 °C; the ambient wet-bulb temperature is 25 °C. The approach, in K, is ____.
Numerical answer — type the value.
Show answer
Answer: 5
Approach = cold-water outlet − wet-bulb = 30 − 25 = 5 K. The range is 40 − 30 = 10 K, the tempting confusion; the approach measures how close the tower gets to its thermodynamic limit.An adsorbent follows the Freundlich isotherm q = Kc^(1/n) with K = 2 and n = 2 (consistent units). At c = 9, the loading q is ____.
Numerical answer — type the value.
Show answer
Answer: 6
q = 2 × 9^(1/2) = 6. Using c^n (162) inverts the exponent; with n > 1 the isotherm is favourable and flattens at high concentration.A batch dryer holds 100 kg dry solid on 10 m² and dries at a constant rate of 2 kg/m²·h. The time to go from X = 0.4 to 0.2 kg/kg (both above X_c), in h, is ____.
Numerical answer — type the value.
Show answer
Answer: 1
t = W_s(X₁ − X₂)/(AN_c) = 100 × 0.2/20 = 1 h. Using the wet mass of solid in place of W_s overstates the time; the falling-rate logarithmic form does not apply above X_c.An RO membrane has water permeability 1 L/m²·h·bar. With 60 bar applied and an osmotic-pressure difference of 28 bar, the water flux, in L/m²·h, is ____.
Numerical answer — type the value.
Show answer
Answer: 32
J_w = A(ΔP − Δπ) = 1 × 32 = 32 LMH. Using the full 60 bar ignores the osmotic back-pressure that the applied pressure must first overcome.Moist air at 30 °C has absolute humidity 0.02 kg/kg dry air. With H = (1.005 + 1.88Y)T + 2501Y kJ/kg dry air (reference 0 °C), its enthalpy, in kJ/kg dry air (two decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 81.30
Humid heat c_s = 1.005 + 1.88 × 0.02 = 1.0426, so H = 1.0426 × 30 + 2501 × 0.02 = 31.28 + 50.02 = 81.30 kJ/kg. Leaving out the latent term 2501Y gives 31.28 kJ/kg and ignores that most of the enthalpy sits in the vapour.Which statements about extraction and leaching are correct?
Show answer
Answer: A — Leaching is solid–liquid extraction of a soluble component from a solid.; C — An extraction factor greater than 1 reduces the number of counter-current stages needed.; D — The raffinate is the feed phase after solute has been removed from it.
Leaching uses a liquid on a solid; a larger E = KS/B strips solute faster per stage; the raffinate is the depleted feed. Counter-current contact keeps the driving force high throughout and needs LESS solvent than cross-current for the same recovery, so the last statement is reversed.