Mass Transfer at Working Depth: Diffusion Fluxes, Mass-Transfer Theories and Analogies, Overall Coefficients, Distillation (Fenske, Underwood, McCabe–Thiele) and Absorber Design with HTU and NTU

Section 6 of the CH paper lists Fick's laws, molecular diffusion in fluids, mass transfer coefficients, the film, penetration and surface-renewal theories, momentum-heat-mass analogies, stage-wise and continuous contacting, stage efficiencies, HTU and NTU, and the design of distillation and absorption — and the existing chapter has the definitions but not one design calculation. Water evaporating through a 10 cm stagnant air film at 25 °C flows at 0.338 mmol/m²s; a binary column separating 40 mol% feed to 95% and 5% at α = 2.5 needs a minimum of 6.43 stages at total reflux and a minimum reflux ratio of 1.444, and stepping off McCabe–Thiele at R = 2.167 gives 12 theoretical stages with the feed on stage 6; an absorber recovering 90% with m = 1.5 and L/G = 2.25 has N_OG = 4.16 and a packed height of 2.50 m for H_OG = 0.6 m.
Overview

Fick's Laws and Molecular Diffusion in Gases and Liquids

2 min read · 1 part

Fick's first law for a binary: J_A = −D_AB dC_A/dz (molar flux relative to the mean molar velocity); the total flux is N_A = J_A + y_A(N_A + N_B). Equimolar counter-diffusion (N_B = −N_A, as in an ideal binary distillation) gives N_A = D_AB(C_A1 − C_A2)/z. Diffusion of A through stagnant B (N_B = 0, evaporation or absorption) gives N_A = (D_ABP/RTz)ln[(P − p_A2)/(P − p_A1)]. For water at 25 °C (p_A1 = 3.169 kPa, p_A2 = 0) evaporating through z = 0.1 m of still air (D = 2.6×10⁻⁵ m²/s, P = 101.325 kPa): N_A = 0.338 mmol/m²s; the equimolar form would give 0.333, a 1.5% lower value, because the bulk-flow term enlarges the stagnant-film flux by the factor P/p_B,lm. Fick's second law ∂C/∂t = D∂²C/∂z² governs unsteady diffusion and mirrors the heat equation.

Diffusivities. Gas-phase D ∝ T^1.75/P (Fuller) and is of order 10⁻⁵ m²/s; for 298 → 350 K at 2 atm: D = 2.6×10⁻⁵ × (350/298)^1.75/2 = 1.72e-05 m²/s. Liquid-phase D is of order 10⁻⁹ m²/s, four orders smaller, and rises with T/μ; the Wilke–Chang estimate D = 7.4×10⁻⁸(φM_B)^0.5T/(μV_A^0.6) cm²/s (φ = 2.6 for water, μ in cP, V_A the molar volume at the normal boiling point in cm³/mol) gives, for a solute with V_A = 60 cm³/mol in water at 298 K and 0.89 cP, 1.45e-05 cm²/s = 1.45e-09 m²/s. Solids: D ~ 10⁻¹⁰ to 10⁻¹⁵ m²/s. Because liquid D is 10⁴ times smaller, liquid-phase resistances dominate the absorption of sparingly soluble gases, whereas gas-phase resistance controls the absorption of very soluble gases such as NH₃ and HCl.

QuantityValue
Water evaporating through 0.1 m still air, 25 °C0.338 mmol/m²s
Gas D at 350 K, 2 atm (from 2.6×10⁻⁵ at 298 K, 1 atm)1.72e-05 m²/s
Wilke–Chang D in water, V_A = 601.45e-09 m²/s
Typical solid D10⁻¹⁰ to 10⁻¹⁵ m²/s

Fick's first law for a binary: J_A = −D_AB dC_A/dz (molar flux relative to the mean molar velocity); the total flux is N_A = J_A + y_A(N_A + N_B). Equimolar counter-diffusion (N_B = −N_A…

Film, Penetration and Surface-Renewal Theories, Analogies and Overall Coefficients

1 min read · 1 part

The film theory puts all resistance in a stagnant film of thickness δ: k_c = D/δ, so k ∝ D. The penetration theory (Higbie) exposes each element for a contact time t_c: k_c = 2√(D/πt_c), so k ∝ D^0.5. Surface renewal (Danckwerts) uses a renewal rate s: k_c = √(Ds), also k ∝ D^0.5. For D = 10⁻⁹ m²/s and t_c = 0.1 s: k_c = 1.128e-04 m/s; with s = 2 s⁻¹: k_c = 4.472e-05 m/s. Experiments typically give k ∝ D^(2/3) between the exponents of the film and penetration models, which is the form of the analogies. Chilton–Colburn analogy: j_D = (k_c/V)Sc^(2/3) = j_H = (h/ρc_pV)Pr^(2/3) = f/2 (Fanning). For turbulent pipe flow with f = 0.005, V = 1 m/s and Sc = 1000: k_c = (f/2)V/Sc^(2/3) = 2.50e-05 m/s. Dimensionless groups: Sh = k_cL/D, Sc = ν/D, and Sh = 0.023Re^0.83Sc^(1/3) (Linton–Sherwood) for pipe flow.

Overall coefficients add resistances in series using the equilibrium slope m (y* = mx): 1/K_y = 1/k_y + m/k_x and 1/K_x = 1/(mk_y) + 1/k_x. With k_y = 0.02, k_x = 0.05 and m = 1.5: 1/K_y = 50 + 30 = 80, K_y = 0.0125 and the gas phase holds 62.5% of the resistance. A very soluble gas (small m) is gas-film controlled, a sparingly soluble gas (large m) liquid-film controlled; the flux is N_A = K_y(y − y*) = k_y(y − y_i) = k_x(x_i − x). The momentum, heat and mass analogies (Reynolds, Prandtl, von Kármán, Chilton–Colburn) assume the same eddy transport for all three; they fail when form drag is present and for high Sc or Pr.

Theoryk_cDependence on D
FilmD/δD¹
Penetration (Higbie)2√(D/πt_c)D^0.5
Surface renewal (Danckwerts)√(Ds)D^0.5
Chilton–Colburn (experiment)(f/2)V Sc^(−2/3)D^(2/3)

The film theory puts all resistance in a stagnant film of thickness δ: k_c = D/δ, so k ∝ D. The penetration theory (Higbie) exposes each element for a contact time t_c: k_c = 2√(D/πt_c), so…

Distillation Design Numbers: Fenske, Underwood, Gilliland and McCabe–Thiele

2 min read · 2 parts

Take a binary with constant relative volatility α = 2.5, feed 100 kmol/h of 40 mol% light component as saturated liquid (q = 1), distillate x_D = 0.95 and bottoms x_B = 0.05. Mass balance: D = F(x_F − x_B)/(x_D − x_B) = 38.89, B = 61.11 kmol/h. Total reflux: the Fenske equation N_min = ln[(x_D/(1 − x_D))((1 − x_B)/x_B)]/ln α = ln(361)/ln 2.5 = 6.43 stages (including the reboiler). Minimum reflux for a saturated-liquid feed and constant α: R_min = [1/(α − 1)][x_D/x_F − α(1 − x_D)/(1 − x_F)] = 1.444; operating at R = 1.5R_min = 2.167. The Gilliland correlation (Molokanov form) with X = (R − R_min)/(R + 1) = 0.2281 gives Y = (N − N_min)/(N + 1) = 0.4369, so N = 12.2 stages. The short-cut estimates bracket the plate count; the rigorous count is by stepping.

McCabe–Thiele stepping. Equilibrium y = αx/[1 + (α − 1)x]. Reflux L = R D = 84.26 and V = L + D = 123.15 kmol/h; the rectifying line is y = [R/(R + 1)]x + x_D/(R + 1) = 0.6842x + 0.3, and with q = 1 the stripping section has L′ = L + F = 184.26 and V′ = V, giving y = (L′/V′)x − (B/V′)x_B. Stepping down from y = x_D = 0.95 with total condenser, switching lines when x passes x_F = 0.4, the script reaches x_B after 12 theoretical stages (the last is the reboiler) with the optimum feed on stage 6. Murphree stage efficiency E_M = (y_n − y_(n+1))/(y_n* − y_(n+1)); with an overall column efficiency of 70%, the number of actual trays is 12/0.7 → 18 (counting the reboiler as a stage; one fewer tray in practice). A partial condenser or reboiler counts as an equilibrium stage; a total condenser does not. Increasing R beyond R_min lowers stages and raises reboiler duty; the total cost has a minimum near R = 1.2–1.5R_min.

QuantityValue
Distillate D and bottoms B38.89 and 61.11 kmol/h
Fenske N_min6.43
R_min and R = 1.5R_min1.444; 2.167
Gilliland N / McCabe–Thiele N, feed stage12.2 / 12; 6
Actual trays at 70% overall efficiency18
Short-cut design for the worked column
  1. Mass balanceD = 38.89, B = 61.11 kmol/h
  2. Fenske, total refluxN_min = 6.43 stages
  3. Minimum refluxR_min = 1.444
  4. Operate at 1.5R_minR = 2.167
  5. GillilandN = 12.2 stages

Take a binary with constant relative volatility α = 2.5, feed 100 kmol/h of 40 mol% light component as saturated liquid (q = 1), distillate x_D = 0.95 and bottoms x_B = 0.05. Mass balance…

Absorber Design: Minimum L/G, Kremser Stages, N_OG and H_OG

2 min read · 2 parts

For a dilute-gas absorber with linear equilibrium y* = mx, entering solvent x_in = 0, y_in = 0.02, 90% recovery (y_out = 0.002) and m = 1.5: the minimum liquid-to-gas ratio (outlet liquid in equilibrium with the inlet gas) is (L/G)_min = m(1 − y_out/y_in) = 1.35; the operating ratio L/G = 2.25 is 1.67 times that, and the absorption factor is A = L/(mG) = 1.50. The Kremser equation gives the number of ideal stages N = ln[((y_in − mx_in)/(y_out − mx_in))(1 − 1/A) + 1/A]/ln A = 3.42. The packed-column design uses the transfer-unit method: Z = H_OG × N_OG, with N_OG = [1/(1 − 1/A)]ln[(1 − 1/A)((y_in − mx_in)/(y_out − mx_in)) + 1/A] = 4.16. For H_OG = 0.6 m: Z = 2.50 m. The height equivalent to a theoretical plate is HETP = Z/N = 0.73 m, and H_OG = G/(K_ya).

Choosing the operating point. Raising L/G lowers the packed height but raises solvent circulation and regeneration cost; designs sit at 1.2 to 2 times the minimum. At the minimum the column needs infinite height (a pinch at the bottom). In the stripper the roles reverse: the stripping factor S = mG/L plays the part of 1/A. For concentrated gases the operating line is curved and the integral ∫dy/(y − y*) is evaluated graphically or numerically; with a straight operating line and equilibrium line the log-mean driving force gives N_OG = (y_in − y_out)/(Δy)_lm. Flooding fixes the maximum gas rate through the generalised pressure-drop correlation (Eckert/Leva), and column diameter follows from operating at 50–70% of flooding.

QuantityValue
Minimum L/G for 90% recovery, m = 1.51.35
Absorption factor A at L/G = 2.251.50
Kremser ideal stages3.42
N_OG and Z at H_OG = 0.6 m4.16; 2.50 m
HETP = Z/N0.73 m
🎯 Fenske minimum stages, worked
The Fenske equation gives the minimum number of stages at total reflux, N_min = ln[(x_D/(1 − x_D))((1 − x_B)/x_B)] / ln α. For x_D = 0.95, x_B = 0.05 and α = 2.5, the bracket is 19 × 19 = 361 and ln 361 = 5.89, while ln 2.5 = 0.916, so N_min = 6.4 stages, which includes the reboiler. The actual number is larger, commonly found from Gilliland's correlation as a function of the ratio of the actual reflux to the minimum.

For a dilute-gas absorber with linear equilibrium y* = mx, entering solvent x_in = 0, y_in = 0.02, 90% recovery (y_out = 0.002) and m = 1.5: the minimum liquid-to-gas ratio (outlet liquid…

Key takeaways

  • Stagnant-film flux N_A = (D P/RTz)ln[(P − p_A2)/(P − p_A1)]; gas D ∝ T^1.75/P; liquid D is about 10⁴ times smaller; Wilke–Chang D ∝ T/(μV_A^0.6).
  • Film k ∝ D, penetration and surface renewal k ∝ D^0.5, experiment about D^(2/3); Chilton–Colburn j_D = j_H = f/2; 1/K_y = 1/k_y + m/k_x.
  • Fenske gives N_min at total reflux; Underwood R_min = [1/(α − 1)][x_D/x_F − α(1 − x_D)/(1 − x_F)] for q = 1; Gilliland links R and N; McCabe–Thiele steps with the q-line.
  • Absorber: (L/G)_min = m × recovery, A = L/(mG), Kremser N, Z = H_OG N_OG, HETP = Z/N; operate at 1.2–2 times the minimum.

Practice questions (24)

Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.

  1. Water evaporates at 25 °C (vapour pressure 3.169 kPa) through 0.1 m of stagnant air at 101.325 kPa (D = 2.6×10⁻⁵ m²/s). The molar flux in mmol/m²s (three decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.338

    N_A = (DP/RTz)ln[P/(P − p_A1)] = (2.6×10⁻⁵ × 101325/(8.314 × 298 × 0.1)) × ln(1.0323) = 0.338 mmol/m²s.
  2. In the penetration theory of mass transfer the coefficient k_c varies with the molecular diffusivity as:

    1. D^1
    2. D^0.5
    3. D^(2/3)
    4. D^0
    Show answer

    Answer: B — D^0.5

    Higbie gives k_c = 2√(D/πt_c); the film theory gives D¹, and experiment sits near D^(2/3), between the two.
  3. With k_y = 0.02 and k_x = 0.05 (mole-fraction units) and equilibrium slope m = 1.5, the overall gas-phase coefficient K_y (four decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 0.0125

    1/K_y = 1/0.02 + 1.5/0.05 = 50 + 30 = 80, so K_y = 0.0125; the gas film holds 62.5% of the resistance.
Show the other 21 questions
  1. Turbulent flow with Fanning f = 0.005, V = 1 m/s and Sc = 1000 gives, by the Chilton–Colburn analogy, a mass transfer coefficient k_c in m/s of (scientific notation, two significant figures, enter as 2.5e-5):

    Numerical answer — type the value.

    Show answer

    Answer: 2.5e-5

    k_c = (f/2)V/Sc^(2/3) = 0.0025 × 1/100 = 2.5e-05 m/s.
  2. A binary mixture has α = 2.5, a saturated-liquid feed of 40 mol%, distillate 95 mol% and bottoms 5 mol%. The Fenske minimum number of stages is (two decimals):

    Numerical answer — type the value.

    Show answer

    Answer: 6.43

    N_min = ln[(0.95/0.05)(0.95/0.05)]/ln 2.5 = ln 361/0.9163 = 6.43.
  3. For the same column, the Underwood minimum reflux ratio for a saturated-liquid feed (q = 1) is (three decimals):

    Numerical answer — type the value.

    Show answer

    Answer: 1.444

    R_min = [1/1.5][0.95/0.4 − 2.5 × 0.05/0.6] = (2.375 − 0.2083)/1.5 = 1.444.
  4. As the reflux ratio is raised from R_min towards total reflux, the number of theoretical stages:

    1. falls while the duties also fall
    2. falls from infinity to N_min while condenser and reboiler duties rise
    3. rises from N_min to infinity
    4. stays constant
    Show answer

    Answer: B — falls from infinity to N_min while condenser and reboiler duties rise

    At R_min a pinch needs infinite stages; at total reflux the stages are N_min (Fenske) but no product is withdrawn. Duty rises with R, which is why cost is minimised near 1.2–1.5R_min.
  5. A dilute-gas absorber has m = 1.5, L/G = 2.25, y_in = 0.02, y_out = 0.002 and pure solvent. N_OG (two decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 4.16

    A = L/(mG) = 1.5; N_OG = [1/(1 − 1/A)]ln[(1 − 1/A)(y_in/y_out) + 1/A] = 3 ln[(1/3)(10) + 2/3] = 3 ln 4 = 4.16.
  6. With H_OG = 0.6 m and the N_OG of the previous absorber, the packed height in m (two decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 2.50

    The transfer-unit method gives the packed height as Z = H_OG × N_OG = 0.6 × 4.159 = 2.50 m.
  7. Which statements about absorber design are correct?

    1. A very soluble gas has a gas-film controlled mass transfer
    2. Raising L/G increases the required packed height
    3. At the minimum L/G the packed height is infinite
    4. Z = H_OG/N_OG
    Show answer

    Answer: A — A very soluble gas has a gas-film controlled mass transfer; C — At the minimum L/G the packed height is infinite

    The minimum ratio corresponds to a pinch and infinite height; small m means the gas film dominates. Raising L/G reduces height, and Z = H_OG × N_OG.
  8. The binary diffusivity of a gas pair at about 1 atm and room temperature is typically of the order of

    1. 10⁻¹² m²/s
    2. 1 m²/s
    3. 10⁻⁹ m²/s
    4. 10⁻⁵ m²/s
    Show answer

    Answer: D — 10⁻⁵ m²/s

    Gas diffusivities are around 10⁻⁵ m²/s (0.1 cm²/s). 10⁻⁹ m²/s is typical of liquids, about ten thousand times slower, and 10⁻¹² m²/s or less is typical of solids.
  9. An ideal-gas mixture at 100 kPa contains A at a partial pressure of 20 kPa. The mole fraction of A (one decimal) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.2

    Dalton: y_A = p_A/P = 20/100 = 0.2. Dividing by the partial pressure of the rest (20/80 = 0.25) gives a mole ratio, not a mole fraction.
  10. In the film theory of mass transfer, the coefficient k_c depends on the diffusivity D as

    1. k_c independent of D
    2. k_c ∝ D
    3. k_c ∝ D^(2/3)
    4. k_c ∝ D^(1/2)
    Show answer

    Answer: B — k_c ∝ D

    k_c = D/δ, linear in D. The square-root dependence comes from the penetration and surface-renewal theories, and D^(2/3) from boundary-layer theory; experiments usually fall between 0.5 and 1.
  11. The Schmidt number is defined as

    1. α/D_AB
    2. ν/D_AB
    3. ν/α
    4. k_cL/D_AB
    Show answer

    Answer: B — ν/D_AB

    Sc = ν/D compares momentum and mass diffusivities, the mass-transfer analogue of Pr. k_cL/D is the Sherwood number, α/D is the Lewis number, and ν/α is the Prandtl number.
  12. A column runs at reflux ratio R = 3. The slope of its rectifying-section operating line (two decimals) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.75

    Slope = L/V = R/(R + 1) = 3/4 = 0.75. Using R itself (3) gives a slope above 1, impossible for the rectifying line, whose L is always less than V.
  13. For R = 3 and x_D = 0.9, the rectifying operating line meets the y-axis (x = 0) at y = ____ (three decimals).

    Numerical answer — type the value.

    Show answer

    Answer: 0.225

    y = Rx/(R + 1) + x_D/(R + 1), so the intercept is 0.9/4 = 0.225. Using x_D/R = 0.300 mis-states the denominator; the line also passes through (x_D, x_D).
  14. An absorber operates with L/G = 3 and equilibrium slope m = 1.5. The absorption factor A = L/(mG) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 2

    A = 3/1.5 = 2; A > 1 means the solvent can in principle strip nearly all the solute with enough stages. Multiplying (4.5) inverts the role of m.
  15. With k_y = 0.04, k_x = 0.02 (mole-fraction units) and m = 0.5, the fraction of the total resistance 1/K_y that lies in the gas film (one decimal) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.5

    1/K_y = 1/k_y + m/k_x = 25 + 25 = 50, so the gas film holds 25/50 = 0.5. Comparing 1/k_y with 1/k_x (25 vs 50) without the slope m gives 0.33; solubility shifts where the resistance lies.
  16. A saturated-liquid feed (q = 1) at x_F = 0.5 is separated to x_D = 0.9 with α = 2. The minimum reflux ratio from the pinch at the feed (one decimal) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 1.4

    The pinch is at x = 0.5, y* = 2(0.5)/1.5 = 0.667; R_min = (x_D − y)/(y − x*) = 0.233/0.167 = 1.4. Using the slope R_min/(R_min + 1) = 0.583 as if it were R_min is the usual slip.
  17. 100 mol/h of feed with z_F = 0.4 gives a distillate of x_D = 0.95 and bottoms of x_W = 0.05. The distillate rate, in mol/h (two decimals), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 38.89

    Overall and component balances give D = F(z_F − x_W)/(x_D − x_W) = 100 × 0.35/0.90 = 38.89 mol/h. Using z_F/x_D × F = 42.11 ignores the light component lost in the bottoms.
  18. A gas with y_in = 0.02 is to leave at y_out = 0.002 using solute-free solvent; equilibrium is y = 1.5x. The minimum L/G (two decimals) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 1.35

    At minimum flow the exit liquid reaches equilibrium with the entering gas: x* = 0.02/1.5 = 0.01333, so (L/G)_min = 0.018/0.01333 = 1.35. Answering 1.50 (= m) applies only to complete removal of the solute.
  19. Gas-phase diffusivity scales as T^1.5 at fixed pressure. Raising the temperature from 300 K to 400 K multiplies D by ____ (three decimals).

    Numerical answer — type the value.

    Show answer

    Answer: 1.540

    (400/300)^1.5 = 1.540. Using Celsius temperatures (127/27)^1.5 gives about 10.3, which is meaningless; the kinetic-theory scaling needs absolute temperature.
  20. By penetration theory, if the solute diffusivity is four times larger (same exposure time), the mass-transfer coefficient is multiplied by ____.

    Numerical answer — type the value.

    Show answer

    Answer: 2

    k_c = 2√(D/(πt)), so k scales as √D: √4 = 2. Film theory would predict 4 (k ∝ D), the tempting answer if the theories are swapped.
  21. A tray absorber with solute-free solvent and absorption factor A = 1.5 must recover 90 % of the solute. By the Kremser equation, the number of ideal stages (three decimals) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 3.419

    N = ln[(y_in/y_out)(1 − 1/A) + 1/A]/ln A = ln[10 × (1/3) + 2/3]/ln 1.5 = ln 4/ln 1.5 = 3.419. Dropping the (1 − 1/A) weighting gives ln 10/ln 1.5 = 5.679, too many stages.