Chemical Engineering for the Junior Engineer Papers: Material Balances, Fluid Flow, Heat Transfer, Mass Transfer and Reaction Engineering
2. Fluid flow, Reynolds number and pumps
The Reynolds number Re = ρvD ÷ μ separates smooth layered (laminar) flow from chaotic (turbulent) flow. In a pipe, flow is laminar below about 2,100 and turbulent above about 4,000, with a transition between. Water of density 1,000 kg/m³ and viscosity 0.001 Pa·s at 2 m/s in a 50 mm pipe has Re = 1,000 × 2 × 0.05 ÷ 0.001 = 100,000, firmly turbulent. Bernoulli's equation adds pressure, kinetic and potential heads along a streamline with no friction; real pipes add a friction loss.
- Pump hydraulic power = ρ g Q H; shaft power = that ÷ efficiency. For Q = 0.01 m³/s, H = 20 m, η = 0.6: 1,000 × 9.81 × 0.01 × 20 ÷ 0.6 ≈ 3.27 kW.
- Centrifugal pumps suit large flows of thin liquids and must be primed; positive-displacement pumps (gear, piston) suit viscous liquids and give a near-constant flow against any pressure.
- Cavitation is bubble formation where local pressure falls below the vapour pressure; it pits impellers and is avoided by keeping the suction head adequate.
- Orifice and venturi meters infer flow from a pressure drop; flow varies as the square root of the drop.
The Reynolds number Re = ρvD ÷ μ separates smooth layered (laminar) flow from chaotic (turbulent) flow. In a pipe, flow is laminar below about 2,100 and turbulent above about 4,000, with a…
3. Heat transfer and heat exchangers
Conduction obeys Fourier's law, q = kAΔT ÷ L. For layers in series the resistances add, R = Σ L ÷ kA, and the heat flow is ΔT ÷ ΣR: a 0.2 m layer of k = 1 and a 0.1 m layer of k = 0.5 W/m·K across 100 °C pass 100 ÷ (0.2 + 0.2) = 250 W per m². Convection uses q = hAΔT and radiation follows the fourth power of absolute temperature.
In a heat exchanger the duty is Q = U A ΔT_lm, where the log-mean temperature difference is (ΔT₁ − ΔT₂) ÷ ln(ΔT₁ ÷ ΔT₂). With end differences of 60 °C and 20 °C it is 40 ÷ ln 3 ≈ 36.4 °C, a little under the arithmetic mean of 40 °C. Counter-current flow gives a larger mean difference than parallel flow for the same terminal temperatures, so it needs less area.
Conduction obeys Fourier's law, q = kAΔT ÷ L. For layers in series the resistances add, R = Σ L ÷ kA, and the heat flow is ΔT ÷ ΣR: a 0.2 m layer of k = 1 and a 0.1 m layer of k = 0.5 W/m·K…
4. Mass transfer, distillation and reaction engineering
Distillation separates liquids by volatility. For an ideal mixture Raoult's law gives the partial pressure p = x P°. A mixture with x_A = 0.4, P°_A = 100 kPa and P°_B = 50 kPa exerts 0.4 × 100 + 0.6 × 50 = 70 kPa, and the vapour is richer in the volatile component: y_A = 40 ÷ 70 ≈ 0.57. Absorption moves a gas into a liquid, extraction moves a solute between two liquids, and drying and crystallisation remove or form phases.
In reaction engineering a first-order reaction has rate = kC and half-life t½ = 0.693 ÷ k, independent of concentration; for k = 0.0231 per minute the half-life is 30 minutes. A batch reactor is loaded, run and emptied; a CSTR is perfectly mixed so its content equals its outlet; a plug-flow reactor has no mixing along the flow. For the same positive-order reaction a plug-flow reactor needs less volume than a CSTR for the same conversion, because it keeps the concentration, and hence the rate, high.

Distillation separates liquids by volatility. For an ideal mixture Raoult's law gives the partial pressure p = x P°. A mixture with x_A = 0.4, P°_A = 100 kPa and P°_B = 50 kPa exerts 0.4 ×…
5. Worked problems: recycle, heat exchangers and flow regimes
Two calculations decide most chemical-engineering numericals. The first is a recycle balance. A reactor that converts only part of its feed in one pass is followed by a separator that returns the unreacted material. Single-pass conversion is what the reactor achieves from its own feed; overall conversion counts only the fresh feed and, with complete recycle and no purge, is 100%. Take a fresh feed of 100 kmol/h and a single-pass conversion of 40%. At steady state all the fresh feed must eventually react, so 0.4 × (reactor feed) = 100 and the reactor feed is 250 kmol/h, of which 150 kmol/h is recycle. A purge is a small bleed taken from the recycle to stop inert gas accumulating; it makes the overall conversion fall below 100%.
| Quantity | Relation | Remember |
|---|---|---|
| Sensible heat | Q = m c ΔT | Use kg/s and kJ/kg·K to get kW |
| Exchanger duty | Q = U A × LMTD | Use LMTD, not the arithmetic mean, when the two end differences differ |
| Log-mean temperature difference | LMTD = (ΔT₁ − ΔT₂) ÷ ln(ΔT₁ ÷ ΔT₂) | Always a little below the arithmetic mean |
| Reynolds number | Re = ρ v D ÷ μ | Below about 2,100 laminar; above about 4,000 turbulent |
A heat-exchanger example: hot oil is cooled from 100 °C to 60 °C while 2 kg/s of water is heated from 20 °C to 50 °C in counter-current flow. The duty is Q = 2 × 4.2 × 30 = 252 kW. The end differences are 100 − 50 = 50 K and 60 − 20 = 40 K, so LMTD = 10 ÷ ln 1.25 = 44.8 K. With U = 0.5 kW/m²·K the area is 252 ÷ (0.5 × 44.8) = 11.25 m².
Two calculations decide most chemical-engineering numericals. The first is a recycle balance. A reactor that converts only part of its feed in one pass is followed by a separator that…
Second Pass: Evaporator Balance, Flow Regime, Heat Duty, Conduction and Relative Volatility
A material balance on the unchanging solute fixes an evaporator: solute in = solute out. Flow in a pipe is laminar below Re ≈ 2,100 and turbulent above about 4,000. Heat duty Q = UAΔT_lm, and conduction through a slab is q = kAΔT/L. Relative volatility is α = (yA/xA)/(yB/xB).
| Item | Working | Answer |
|---|---|---|
| 1,000 kg/h of 20% brine to 40% | salt 200; product 500 | water evaporated 500 kg/h |
| ρ = 900, μ = 0.09, v = 1, D = 0.1 | 900 × 1 × 0.1/0.09 | Re = 1,000, laminar |
| U = 500, A = 10, ΔT_lm = 40 | 500 × 10 × 40 | 200 kW |
| y = 0.6 at x = 0.4 | (0.6/0.4)/(0.4/0.6) | α = 2.25 |
A material balance on the unchanging solute fixes an evaporator: solute in = solute out. Flow in a pipe is laminar below Re ≈ 2,100 and turbulent above about 4,000. Heat duty Q = UAΔT_lm…
Key takeaways
- Mass balance: accumulation = in − out + generation − consumption; find the limiting reactant by comparing mole ÷ coefficient.
- Re = ρvD ÷ μ: laminar below about 2,100, turbulent above about 4,000; pump power = ρgQH ÷ η.
- Series resistances add; heat-exchanger duty is UA times the log-mean temperature difference, and counter-current beats parallel flow.
- Raoult's law p = xP° explains distillation; first-order half-life is 0.693 ÷ k; a plug-flow reactor is smaller than a CSTR for positive-order kinetics.
- Recycle: reactor feed = fresh feed ÷ single-pass conversion; LMTD = (ΔT₁ − ΔT₂) ÷ ln(ΔT₁ ÷ ΔT₂), always below the arithmetic mean.
Practice questions (25)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
In the reaction N₂ + 3H₂ → 2NH₃, 28 kg of nitrogen and 8 kg of hydrogen are fed. The maximum mass of ammonia that can form is:
Show answer
Answer: A — 34 kg
Nitrogen is 1 kmol and hydrogen 4 kmol. One kmol of N₂ needs only 3 kmol of H₂, so nitrogen is limiting and gives 2 kmol of NH₃, which is 2 × 17 = 34 kg. The 68 kg figure assumes both reactants are fully used.A feed of 5 kmol of a reactant is converted to the extent of 80%. The amount that reacts is:
Show answer
Answer: B — 4 kmol
Conversion is the fraction reacted, so 0.8 × 5 = 4 kmol reacts and 1 kmol leaves unreacted. Giving 1 kmol answers the question of what remains, not what reacts.Water (ρ = 1,000 kg/m³, μ = 0.001 Pa·s) flows at 2 m/s through a pipe of 50 mm diameter. The Reynolds number is:
Show answer
Answer: B — 100,000, turbulent
Re = ρvD ÷ μ = 1,000 × 2 × 0.05 ÷ 0.001 = 100,000, far above 4,000, so the flow is turbulent. Using the diameter in millimetres (50 instead of 0.05) would give an absurd million-fold error.
Show the other 22 questions
A pump delivers 0.01 m³/s of water against a head of 20 m with an overall efficiency of 60%. Taking g = 9.81 m/s², the shaft power needed is about:
Show answer
Answer: B — 3.27 kW
Hydraulic power is ρgQH = 1,000 × 9.81 × 0.01 × 20 = 1,962 W, and dividing by the efficiency 0.6 gives 3,270 W. The 1.96 kW figure is the useful power and forgets the losses, which the efficiency accounts for.A wall has two layers in series: 0.2 m of material with k = 1 W/m·K and 0.1 m with k = 0.5 W/m·K. With a 100 °C difference across it, the heat flow per square metre is:
Show answer
Answer: A — 250 W
The series resistance per unit area is 0.2 ÷ 1 + 0.1 ÷ 0.5 = 0.4 m²K/W, so the flow is 100 ÷ 0.4 = 250 W/m². Adding the conductivities or using only one layer ignores that resistances in series add.The temperature differences between the hot and cold streams at the two ends of a heat exchanger are 60 °C and 20 °C. The log-mean temperature difference is about:
Show answer
Answer: B — 36.4 °C
LMTD = (60 − 20) ÷ ln(60 ÷ 20) = 40 ÷ ln 3 = 40 ÷ 1.0986 ≈ 36.4 °C. It is always below the arithmetic mean (40 °C) unless the end differences are equal, which is why using the plain average slightly over-estimates the heat transfer.An ideal liquid mixture has 0.4 mole fraction of A (pure vapour pressure 100 kPa) and 0.6 of B (50 kPa). By Raoult's law the total vapour pressure is:
Show answer
Answer: B — 70 kPa
The total is the sum of the partial pressures, 0.4 × 100 + 0.6 × 50 = 40 + 30 = 70 kPa. The simple mean of the two pure pressures (75 kPa) ignores the composition, which is what Raoult's law weights by.A first-order reaction has a rate constant of 0.0231 per minute. Its half-life is about:
Show answer
Answer: B — 30 minutes
For a first-order reaction t½ = ln 2 ÷ k = 0.693 ÷ 0.0231 = 30 minutes, whatever the starting concentration. Calculating 1 ÷ k (43 minutes) gives the mean life, not the half-life.Fresh feed of 100 kmol/h goes to a reactor with a single-pass conversion of 40%. The unreacted material is recycled completely and there is no purge. The recycle rate is:
Show answer
Answer: A — 150 kmol/h
All 100 kmol/h of fresh feed must react, so 0.4 × reactor feed = 100, giving a reactor feed of 250 kmol/h; the recycle is 250 − 100 = 150 kmol/h. The figure 250 is the reactor feed, not the recycle.A heat exchanger has end temperature differences of 60 K and 20 K. Its log-mean temperature difference is nearest to:
Show answer
Answer: A — 36.4 K
LMTD = (60 − 20) ÷ ln(60 ÷ 20) = 40 ÷ 1.0986 = 36.4 K. The arithmetic mean, 40 K, is the tempting but over-stated value.An evaporator concentrates 1,000 kg/h of a salt solution from 20% to 40% salt. The mass of water evaporated per hour is:
Show answer
Answer: A — 500 kg
Salt = 200 kg/h is unchanged, so the product is 200/0.4 = 500 kg/h and the water removed is 1,000 − 500 = 500 kg/h. The 400 kg/h is the extra salt strength misread as water.Oil of density 900 kg/m³ and viscosity 0.09 Pa·s flows at 1 m/s in a 0.1 m diameter pipe. The Reynolds number and the flow regime are:
Show answer
Answer: A — 1,000 and laminar
Re = ρvD/μ = 900 × 1 × 0.1/0.09 = 1,000, below about 2,100, so the flow is laminar.A heat exchanger has an overall coefficient of 500 W/m²·K, an area of 10 m² and a log-mean temperature difference of 40 K. The heat duty is:
Show answer
Answer: A — 200 kW
Q = UAΔT_lm = 500 × 10 × 40 = 2,00,000 W = 200 kW. The 12.5 kW divides instead of multiplying.A slab of thermal conductivity 0.5 W/m·K, area 2 m² and thickness 0.1 m has a temperature difference of 40 K across it. The heat flow is:
Show answer
Answer: A — 400 W
Q = kAΔT/L = 0.5 × 2 × 40/0.1 = 400 W. Multiplying by the thickness instead of dividing gives 4 W.For a first-order reaction, the fraction of the reactant remaining after three half-lives is:
Show answer
Answer: A — 1/8
Each half-life halves the amount: (1/2)³ = 1/8, independent of the starting concentration. The 1/6 treats the half-lives as additive fractions.In a binary mixture at equilibrium the liquid contains 0.4 mole fraction of A and the vapour contains 0.6 mole fraction of A. The relative volatility of A with respect to B is:
Show answer
Answer: A — 2.25
α = (yA/xA)/(yB/xB) = (0.6/0.4)/(0.4/0.6) = 1.5/0.667 = 2.25. The 1.5 is only the ratio for A and ignores B.Consider the following statements about laminar flow in a circular pipe:
1. The velocity profile is parabolic.
2. The maximum velocity at the centre is twice the average velocity.
Which is/are correct?Show answer
Answer: A — Both 1 and 2
Fully developed laminar pipe flow (Hagen–Poiseuille) has a parabolic profile with u_max = 2 × u_avg. For turbulent flow the profile is flatter and u_max is only about 1.2 u_avg.A mixture contains 3 mol of A and 2 mol of B. The mole fraction of A is:
Show answer
Answer: D — 0.6
x_A = 3 ÷ (3 + 2) = 0.6. The 0.67 is the ratio 2 : 3 turned into a fraction, and 1.5 is the mole ratio A : B.A distillation column receives 100 kg/h of feed containing 40% A. The distillate has 95% A and the bottoms 5% A. The distillate rate is about:
Show answer
Answer: A — 38.9 kg/h
Total balance D + B = 100 and component balance 0.95D + 0.05B = 40 give 0.9D = 35, so D = 38.9 kg/h. Check: bottoms 61.1 kg/h carries 3.06 kg of A, and 36.94 + 3.06 = 40. Taking the feed percentage as the distillate rate (40) is the tempting slip.Water flows in a pipe, and the pipe's diameter is doubled further downstream. By the equation of continuity the velocity there becomes:
Show answer
Answer: D — One-fourth
Area grows with the square of the diameter, so doubling the diameter quadruples the area and cuts the velocity to one-fourth. One-half is the tempting answer from forgetting the square.For water with Cp = 4,200 J/kg K, viscosity 0.001 Pa·s and thermal conductivity 0.6 W/m K, the Prandtl number is:
Show answer
Answer: C — 7
Pr = Cp × μ ÷ k = 4,200 × 0.001 ÷ 0.6 = 7. Check: 4.2 ÷ 0.6 = 7. The 0.14 is the inverted ratio.A hot body's absolute temperature is doubled. By the Stefan-Boltzmann law the radiant heat emitted per unit area increases by a factor of:
Show answer
Answer: D — 16
Emissive power varies as T⁴, so doubling T gives 2⁴ = 16 times. The factor 4 comes from wrongly using T².In a reactor, 100 mol of A is fed and 60 mol reacts to give 45 mol of the desired product (1 : 1 stoichiometry). The conversion and the selectivity for the desired product are:
Show answer
Answer: C — 60% and 75%
Conversion = 60 ÷ 100 = 60%; selectivity = desired formed ÷ reacted = 45 ÷ 60 = 75%. The yield is 45 ÷ 100 = 45%, the tempting figure for selectivity.For laminar flow in a circular pipe the Fanning friction factor is f = 16 ÷ Re. At Re = 800 the friction factor is:
Show answer
Answer: A — 0.02
f = 16 ÷ 800 = 0.02. Check: 0.02 × 800 = 16. Re = 800 is laminar (below about 2,100), so the formula applies. The Darcy factor would be four times larger, the tempting mix-up.For the same terminal temperatures of the two fluids, which flow arrangement in a double-pipe heat exchanger gives the larger log-mean temperature difference?
Show answer
Answer: A — Counter-current flow
Counter-current flow keeps a more uniform temperature difference along the exchanger, so its LMTD is larger and less area is needed. The "same value" choice is the tempting error.