Mine Ventilation and Ground Control in Numbers: Atkinson Resistance, Series and Parallel Airways, Fan Power, Gas Dilution, Noise Levels, Stresses Around Openings, Pillars and Slope Stability

Section 5 of the Mining Engineering paper names the mechanics of airflow, dispersion of contamination, noise pollution and the thermal environment, and Section 3 names stress distribution around mine openings, dump stability and equivalent force systems; the first chapters of each state the ideas without a worked case. An airway of 4 × 3 m and 1000 m with Atkinson's k = 0.012 has resistance 0.0972 Ns²/m⁸ and a head loss of 156 Pa at 40 m³/s, an air power of 6.2 kW; two airways of 0.10 and 0.40 in parallel have a combined resistance of 0.0444; 0.05 m³/s of methane needs 5 m³/s to stay at 1%; two 90 dB machines make 93 dB; at 500 m depth the tangential stress at the roof of a circular opening with k = 0.5 is 6.75 MPa against 33.75 MPa in the sidewall; and a dump face of 30° on a 35° friction angle has a safety factor of 1.21.
Overview

Mechanics of Airflow: Resistance, Networks and Fan Power

1 min read

Turbulent flow in a mine airway follows Atkinson's equation: the frictional pressure drop h = k P L V²/A, which with Q = AV becomes h = R Q² with R = k L P/A³ (k, the friction factor, is about 0.012 Ns²/m⁴ for a smooth-timbered or bare-rock roadway, up to 0.02 with rough supports). For a 4 × 3 m airway (A = 12 m², perimeter P = 14 m) of length 1000 m, R = 0.012 × 1000 × 14/12³ = 0.0972 Ns²/m⁸; at Q = 40 m³/s the head loss is h = 0.0972 × 40² = 156 Pa and the air power hQ = 6.2 kW. Because R ∝ 1/A³, enlarging the airway pays: doubling the area cuts the resistance by 8. Networks: in series R adds (R_s = 0.10 + 0.40 = 0.50) and the quantity is common; in parallel the pressure drop is common and 1/√R_p = Σ1/√Rᵢ, so for R₁ = 0.10 and R₂ = 0.40: R_p = 0.0444, and a total of 50 m³/s splits 33.3 and 16.7 m³/s (the lower-resistance branch takes twice the air), at a common head of 111 Pa. A fan delivering 60 m³/s against 1200 Pa has an air power of 72 kW and, at 60% efficiency, takes 120 kW from the shaft. Natural ventilation pressure from the density difference between two shafts of height H is NVP = gH(ρ_downcast − ρ_upcast): for H = 300 m and densities 1.25 and 1.15 kg/m³ it is 294 Pa, which helps in winter and may reverse in summer.

QuantityFormulaValue here
Resistancek L P/A³0.0972 Ns²/m⁸
Head loss at 40 m³/sR Q²156 Pa
Parallel resistance1/(Σ 1/√Rᵢ)²0.0444
Fan shaft powerhQ/η120 kW

Turbulent flow in a mine airway follows Atkinson's equation: the frictional pressure drop h = k P L V²/A, which with Q = AV becomes h = R Q² with R = k L P/A³ (k, the friction factor, is…

Dispersion of Contamination, Noise and the Thermal Environment

1 min read · 1 part

Dilution of a contaminant: the airflow needed to keep a gas below a limit is Q = q/(C_limit − C_intake). Methane emitted at 0.05 m³/s must be held below 1% in a working face, so Q = 0.05/0.01 = 5 m³/s (in practice below 0.75–1% in return air and an alarm at 1.25% and a power cut at 1.5%, as the Indian regulations require; the limits come from the explosive range of 5–15%). Dust and diesel fume are treated the same way, and a ventilation survey compares the quantity at each point with the requirement. Noise levels add logarithmically: L = 10 log₁₀ Σ 10^(Lᵢ/10); two machines at 90 dB give 10 log₁₀(2 × 10⁹) = 93 dB, three unequal sources of 90 and 85 dB give 91.2 dB (the louder source dominates). Doubling the sources adds only 3 dB. Exposure limits are 90 dB(A) for 8 hours with a 5 dB exchange (or 85 dB with 3 dB, in other standards); control by enclosing, silencing, distance and ear protection. Thermal environment: at depth the rock temperature rises by about 1 °C per 30–40 m (the geothermal gradient, in this country with large local variation), and the body is cooled by evaporation, so the wet-bulb temperature and air velocity decide comfort; air-conditioning is needed when wet-bulb temperatures exceed about 28 °C.

ItemRuleValue
Methane dilutionQ = q/C5 m³/s
Two 90 dB sources10 log Σ 10^(L/10)93 dB
90 dB + 85 dB10 log Σ 10^(L/10)91.2 dB
Natural ventilation pressuregH Δρ294 Pa

Dilution of a contaminant: the airflow needed to keep a gas below a limit is Q = q/(C_limit − C_intake). Methane emitted at 0.05 m³/s must be held below 1% in a working face, so Q =…

Stress Distribution Around Openings and Pillar Design

1 min read

Before excavation the vertical stress is σ_v = γH = 0.027 MN/m³ × 500 m = 13.5 MPa at 500 m, and the horizontal stress is kσ_v. For a circular opening the Kirsch solution gives the tangential stress at the boundary: at the roof and floor (crown) σ_θ = (3k − 1)σ_v, in the sidewall σ_θ = (3 − k)σ_v. For hydrostatic k = 1 both equal 2σ_v = 27 MPa (a stress concentration factor of 2). For k = 0.5: roof 6.75 MPa, sidewall 33.75 MPa; for k = 2 (a high horizontal stress): roof 67.5 MPa but sidewall only 13.5 MPa. A negative value at the crown means tension (k < 1/3) and roof failure in a rock with little tensile strength. The stress concentration decays as 1/r² and is negligible beyond about three radii. Pillar design (room-and-pillar): the average pillar stress by tributary area is σ_p = γH((w + B)/w)² for square pillars of width w and rooms B; for w = 10 m, B = 6 m at 150 m: σ_p = 0.027 × 150 × 2.56 = 10.37 MPa. The Obert–Duvall strength σ_pillar = σ₁(0.778 + 0.222w/h), with σ₁ = 40 MPa (the strength of a unit cube) and w/h = 10/3, is 60.7 MPa, so the factor of safety is 5.86 (a design value of about 1.5–2 is used). Wider pillars gain strength by confinement, and the extraction ratio is 1 − (w/(w + B))² = 61%.

Position / quantityFormulaValue
σ_v at 500 mγH13.5 MPa
Roof, k = 0.5(3k − 1)σ_v6.75 MPa
Sidewall, k = 0.5(3 − k)σ_v33.75 MPa
Pillar factor of safetyσ_pillar/σ_p5.86

Before excavation the vertical stress is σ_v = γH = 0.027 MN/m³ × 500 m = 13.5 MPa at 500 m, and the horizontal stress is kσ_v. For a circular opening the Kirsch solution gives the…

Dump and Slope Stability: Factors of Safety

2 min read · 1 part

A dump or slope fails when the driving force along a potential slip surface exceeds the resisting force; the factor of safety is FS = resisting/driving, and a value above 1 is safe (design 1.2–1.5 for dumps, more for permanent slopes). For a dry cohesionless dump face at angle β with friction angle φ, the infinite-slope result is FS = tan φ/tan β = tan 35°/tan 30° = 1.21; the slope can never stand steeper than the angle of repose (β ≤ φ for FS ≥ 1). For a plane failure in a bench with cohesion c over a slip area A, weight W of the sliding block and plane dip ψ: FS = (cA + W cos ψ tan φ)/(W sin ψ). With c = 25 kPa, A = 120 m², W = 5000 kN, ψ = 35°, φ = 30°: resisting = 3000 + 5000 × 0.819 × 0.577 = 5365 kN, driving = 5000 × 0.574 = 2868 kN, so FS = 1.87. Water pressure on the plane reduces the normal force and the friction and is the commonest cause of failure; drainage (horizontal drains, sumps) raises FS faster than flattening the slope. Equivalent force systems (the engineering-mechanics heading) reduce a set of forces to a resultant force and a couple at a chosen point — the first step in finding the force on a retaining wall or the line of thrust of a dump.

CaseFormulaFS
Dry cohesionless slope, 30° on φ = 35°tan φ/tan β1.21
Plane failure with cohesion(cA + W cos ψ tan φ)/(W sin ψ)1.87
Design FS, dumpsNot below1.2–1.5
🎯 Atkinson's law and airway networks
The pressure drop in a mine airway is p = RQ², with R = kLP/A³ (k the friction factor, L length, P perimeter, A area), so halving the area multiplies the resistance eightfold. Airways in series add resistances, R = R₁ + R₂; in parallel 1/√R = Σ 1/√Rᵢ, so two equal airways give R = R₁/4 and pass twice the quantity at the same pressure. Air power is pQ: 1000 Pa at 50 m³/s is 50 kW, and the fan input is larger by the fan efficiency.

A dump or slope fails when the driving force along a potential slip surface exceeds the resisting force; the factor of safety is FS = resisting/driving, and a value above 1 is safe (design…

Key takeaways

  • Atkinson: h = RQ² with R = kLP/A³; resistances add in series, 1/√R adds in parallel; fan shaft power = hQ/η.
  • Dilution airflow Q = q/C; noise adds logarithmically (two equal sources add 3 dB); wet-bulb temperature governs heat stress.
  • Kirsch: roof (3k − 1)σ_v and sidewall (3 − k)σ_v around a circular opening; both equal 2σ_v when k = 1.
  • Pillar stress by tributary area is γH((w + B)/w)²; factor of safety = strength/stress.
  • FS = resisting/driving; dry cohesionless slope FS = tan φ/tan β; water pressure is the commonest cause of slope failure.

Practice questions (24)

Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.

  1. An airway 4 m × 3 m (perimeter 14 m, area 12 m²), 1000 m long, with k = 0.012 Ns²/m⁴, carries 40 m³/s. The frictional pressure drop in pascals (nearest integer) is:

    Numerical answer — type the value.

    Show answer

    Answer: 156

    R = kLP/A³ = 0.012 × 1000 × 14/1728 = 0.0972; h = RQ² = 0.0972 × 1600 = 156 Pa. Using A² instead of A³ would give a wrong resistance.
  2. Two airways of resistance 0.10 and 0.40 Ns²/m⁸ are in parallel. Compared with the high-resistance branch, the low-resistance branch carries:

    1. Twice the air, since Q ∝ 1/√R
    2. Four times the air
    3. The same air
    4. Half the air
    Show answer

    Answer: A — Twice the air, since Q ∝ 1/√R

    With a common pressure drop h = RQ², Q = √(h/R), so the ratio of flows is √(0.40/0.10) = 2. Four is the ratio of resistances, which is the usual slip.
  3. Methane is emitted at 0.05 m³/s and must be kept at no more than 1% in the air at the working face. The minimum airflow in m³/s (nearest integer) is:

    Numerical answer — type the value.

    Show answer

    Answer: 5

    Q = 0.05/0.01 = 5 m³/s. Using 1 as the fraction would give 0.05, which is the emission itself.
Show the other 21 questions
  1. Two identical machines each produce 90 dB at a point. The combined sound level in dB (nearest integer) is:

    Numerical answer — type the value.

    Show answer

    Answer: 93

    10 log₁₀(2 × 10⁹) = 90 + 3.01 = 93.0 ≈ 93 dB. Adding the decibels (180) is meaningless.
  2. At 500 m depth (γ = 0.027 MN/m³) with a horizontal-to-vertical stress ratio k = 0.5, the tangential stress at the roof of a circular opening in MPa (two decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 6.75

    σ_v = 13.5 MPa; roof σ_θ = (3k − 1)σ_v = 0.5 × 13.5 = 6.75 MPa. The sidewall carries (3 − k)σ_v = 33.75 MPa, five times more.
  3. For a circular opening in a rock mass with k = 0.2 (low horizontal stress), the stress at the roof is:

    1. Tensile, because 3k − 1 is negative
    2. Compressive and equal to 2σ_v
    3. Zero
    4. Compressive and equal to 3σ_v
    Show answer

    Answer: A — Tensile, because 3k − 1 is negative

    (3 × 0.2 − 1)σ_v = −0.4σ_v, a tensile stress. Rocks have little tensile strength, so the roof is the weak point when the horizontal stress is low — support it with bolts.
  4. A dry cohesionless dump face stands at 30° and the dump material has a friction angle of 35°. The factor of safety against sliding (two decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 1.21

    FS = tan 35°/tan 30° = 0.700/0.577 = 1.21. A face at 35° would have FS = 1 exactly — the angle of repose.
  5. A plane failure has c = 25 kPa over 120 m², block weight 5000 kN, dip 35° and friction angle 30°. The factor of safety (two decimals) is:

    Numerical answer — type the value.

    Show answer

    Answer: 1.87

    FS = (25 × 120 + 5000 cos 35° tan 30°)/(5000 sin 35°) = (3000 + 2365)/2868 = 1.87. Removing the cohesion would give 0.82, i.e. failure.
  6. Which statements are correct?

    1. Water pressure on a slip plane lowers the factor of safety
    2. Resistances of airways in series add
    3. Air power is the pressure drop times the airflow
    4. Stress concentration around an opening persists unchanged beyond ten radii
    Show answer

    Answer: A — Water pressure on a slip plane lowers the factor of safety; B — Resistances of airways in series add; C — Air power is the pressure drop times the airflow

    Air power = hQ, water pressure reduces the effective normal stress and so the friction, and series resistances add. The stress concentration decays as 1/r² and is negligible beyond about three radii.
  7. Air moves at 6 m/s through a 5 m² airway. The air quantity, in m³/s, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 30

    Q = V·A = 6 × 5 = 30 m³/s. Dividing (6/5) misuses the continuity equation Q = VA. Substituting the answer back into the relation confirms it.
  8. An airway of resistance 0.4 Ns²/m⁸ carries 25 m³/s. The pressure loss H = RQ², in Pa, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 250

    H = RQ² = 0.4 × 625 = 250 Pa. Using RQ (0.4 × 25 = 10) drops the square-law dependence. Substituting the answer back into the relation confirms it.
  9. The threshold limit value (TLV) concept for a mine gas specifies

    1. the fan pressure
    2. the concentration to which workers may be exposed without adverse effect
    3. the ignition temperature
    4. the explosive limit
    Show answer

    Answer: B — the concentration to which workers may be exposed without adverse effect

    A TLV is an occupational-exposure limit for health, usually a time-weighted average. The explosive limit and ignition temperature are combustion properties, not exposure limits, the tempting confusions.
  10. Carbon dioxide accumulating in low, poorly ventilated workings is called

    1. whitedamp
    2. blackdamp (stythe)
    3. afterdamp
    4. firedamp
    Show answer

    Answer: B — blackdamp (stythe)

    Blackdamp (chiefly CO₂ with excess N₂) collects low down and suffocates by excluding oxygen. Firedamp is methane and whitedamp is CO, the tempting other damps.
  11. With a rock unit weight of 0.025 MN/m³, the vertical stress at 500 m depth, in MPa, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 12.5

    σ_v = γH = 0.025 × 500 = 12.5 MPa. Using a water unit weight would badly underestimate the overburden. Substituting the answer back into the relation confirms it.
  12. For an infinite dry cohesionless slope at 25° with a friction angle of 35°, the factor of safety FS = tan φ/tan β (two decimals) is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 1.50

    FS = tan 35°/tan 25° = 0.700/0.466 = 1.50, stable since FS > 1. Inverting to tan β/tan φ = 0.67 would wrongly suggest failure.
  13. A fan delivers 25 m³/s against 250 Pa at 50% overall efficiency. The input power, in kW (one decimal), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 12.5

    Air power = 25 × 250 = 6250 W; input = 6250/0.5 = 12 500 W = 12.5 kW. Multiplying by 0.5 instead of dividing gives 3.1 kW, below the air power, which is impossible.
  14. Two airways of resistance 0.3 and 0.4 Ns²/m⁸ are in series. The equivalent resistance, in Ns²/m⁸ (one decimal), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.7

    Series resistances add directly: R_eq = 0.3 + 0.4 = 0.7 Ns²/m⁸. Combining as √R or parallel would be wrong for a series connection.
  15. Two identical machines each produce 90 dB at a point. Their combined sound level, in dB (two decimals), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 93.01

    Combining equal levels: L = 90 + 10·log₁₀2 = 90 + 3.01 = 93.01 dB. Adding arithmetically (90 + 90 = 180) ignores the logarithmic decibel scale.
  16. Diesel exhaust adds a noxious gas at 0.002 m³/s and it must be diluted to 50 ppm (5×10⁻⁵). The minimum airflow Q = q/limit, in m³/s, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 40

    Q = 0.002/(5×10⁻⁵) = 40 m³/s. Using 50 (ppm) directly as the divisor instead of 5×10⁻⁵ underestimates the airflow by 10⁶.
  17. For a dry cohesionless slope, the limiting stable angle equals

    1. zero
    2. 90°
    3. the angle of internal friction
    4. twice the friction angle
    Show answer

    Answer: C — the angle of internal friction

    With no cohesion, FS = 1 when tan β = tan φ, i.e. the slope stands at the friction angle (angle of repose). Twice the friction angle or 90° would be far steeper than stability allows, the tempting errors.
  18. At 600 m depth (γ = 0.025 MN/m³, Poisson’s ratio ν = 0.3), the horizontal stress under uniaxial-strain conditions, σ_h = [ν/(1−ν)]·σ_v, in MPa (two decimals), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 6.43

    σ_v = 0.025 × 600 = 15 MPa; k = ν/(1−ν) = 0.3/0.7 = 0.429; σ_h = 0.429 × 15 = 6.43 MPa. Taking k = ν = 0.3 (omitting the 1−ν) gives 4.5 MPa, underestimating the horizontal stress.
  19. Two airways of resistance 0.4 and 0.9 Ns²/m⁸ run in parallel. Using 1/√R_eq = Σ(1/√R_i), the equivalent resistance, in Ns²/m⁸ (three decimals), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 0.144

    1/√R_eq = 1/√0.4 + 1/√0.9 = 1.581 + 1.054 = 2.635, so R_eq = 1/2.635² = 0.144 Ns²/m⁸. Adding resistances (1.3) or using the electrical parallel rule ignores the square-law of mine resistance.
  20. A worker is exposed to 90 dB for 4 h (8 h permitted) and 95 dB for 2 h (4 h permitted). The total noise dose, as a fraction of the daily limit, is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 1.0

    Dose = Σ(Cᵢ/Tᵢ) = 4/8 + 2/4 = 0.5 + 0.5 = 1.0, i.e. exactly the permissible limit. Averaging the fractions (0.5) instead of summing them halves the true dose.
  21. A dry cohesionless slope has a friction angle of 40°. The slope angle β that gives a factor of safety of 1.3 (FS = tan φ/tan β), in degrees (one decimal), is ____.

    Numerical answer — type the value.

    Show answer

    Answer: 32.9

    tan β = tan 40°/1.3 = 0.839/1.3 = 0.645, so β = 32.9°. Setting β = 40/1.3 = 30.8° divides the angle instead of its tangent, which is not how FS works.