Metrology at Working Depth: Linear and Angular Measurement, Comparators, Interferometry, Form and Finish, Alignment Tests, Tolerance Stack-Up and the CMM
Comparators
A comparator does not read a dimension; it shows the difference between a part and a master (a slip-gauge stack or setting gauge), so the instrument only needs a short, highly magnified range. Magnification M = pointer (or image) movement/spindle movement, and sensitivity is the same ratio; range is the largest deviation readable. A comparator reading 0.001 mm per division with divisions 1.5 mm apart on the scale has M = 1.5/0.001 = 1500. Setting is done at the master (say 25.000 mm), then a part reading +12 divisions is 25.012 mm. The four families: mechanical (dial indicator: rack-and-pinion and gear train; reed type: twin reeds, no friction, M to 5000; Sigma: lever + roller), optical (an optical lever: a tilting mirror and projected scale, M about 1000–2000, no friction or inertia), electrical (LVDT, a differential transformer with output proportional to core displacement and M easily 10⁴ with amplification) and pneumatic (the back-pressure of an air jet changes with the gap to the work; the Solex gauge reaches M of several thousand and measures without contact, so it is used for bores and thin parts).
A comparator does not read a dimension; it shows the difference between a part and a master (a slip-gauge stack or setting gauge), so the instrument only needs a short, highly magnified…
Interferometry: Optical Flats, Fringes and the Laser Interferometer
Two light waves reflected from the two faces of a thin air wedge interfere; a dark fringe appears each time the gap grows by λ/2, because the path difference changes by λ (round trip). For sodium light (λ = 589.3 nm) one fringe is 0.2947 µm of height; for green mercury (546.1 nm) 0.273 µm; for a He–Ne laser (632.8 nm) 0.316 µm. An optical flat (a lapped, flat-to-λ/20 glass disc) is placed on the work: straight, equally spaced, parallel fringes mean the surface is flat; curved fringes mean it is not. If a fringe bows by a relative to the fringe spacing b, the surface departs from flatness by (a/b)(λ/2): with a/b = 0.4, 0.118 µm. A convex surface bows the fringes away from the line of contact (toward the thick end of the wedge) while a concave one bows them toward it. Total fringes across a wedge of thickness h: N = 2h/λ; for h = 25 µm, N = 85. The flats test gauge blocks, micrometer anvils and lapped surfaces to a fraction of a micrometre.
A laser (Michelson) interferometer counts fringes as a mirror moves: displacement = N × λ/2, and with quadrature detection a count every λ/8 (79 nm for He–Ne). A 1 m travel at 632.8 nm is 3,160,556 fringes. Its accuracy is set by the wavelength in air, λ = λ₀/n, where the refractive index n − 1 ≈ 2.7 × 10⁻⁴ varies with temperature (about −1 ppm per °C), pressure (about +0.4 ppm per hPa) and humidity (small): ignoring n entirely would give 270 µm per metre, and an uncompensated 1 °C change about 1 µm per metre — hence the environmental sensors and the compensation that real systems apply. Laser interferometers calibrate machine-tool and CMM axes (linear positioning, straightness, angular and squareness errors) because they trace to the metre's definition by frequency. A Michelson layout splits the beam, sends one to a fixed and one to a moving retro-reflector, and recombines; a Fabry–Perot, with two parallel partial mirrors, gives very sharp fringes for wavelength standards.
| Light source | Wavelength | λ/2 (one fringe) |
|---|---|---|
| Sodium (D line) | 589.3 nm | 0.2947 µm |
| Mercury green | 546.1 nm | 0.2731 µm |
| He–Ne laser | 632.8 nm | 0.3164 µm |
| Cadmium red | 643.8 nm | 0.3219 µm |
Two light waves reflected from the two faces of a thin air wedge interfere; a dark fringe appears each time the gap grows by λ/2, because the path difference changes by λ (round trip). For…
Form and Finish: Roughness Parameters, Straightness, Flatness and Roundness
Surface texture is split into roughness (fine, tool-marks), waviness (longer wavelength) and form, by a cut-off filter (λ_c = 0.8 mm by default, evaluation length 5λ_c = 4 mm). R_a = (1/L)∫|y| dx is the arithmetic mean deviation from the mean line; R_q (rms) = √((1/L)∫y² dx); R_z/R_t are peak-to-valley heights. For ordinates 2, −3, 4, −1, −2, 3, −4, 1 µm: R_a = 20/8 = 2.50 µm, R_q = √(60/8) = 2.74 µm. A turned surface has an ideal peak-to-valley R_max = f²/(8r) (feed f, nose radius r) and R_a ≈ f²/(32r): for f = 0.2 mm/rev, r = 0.8 mm, R_max = 6.25 µm and R_a = 1.56 µm — so halving the feed cuts roughness by four, whereas doubling the nose radius halves it. Stylus profilometers trace the surface with a diamond tip (2–5 µm radius); optical methods (interference microscopes) are non-contact; lay and waviness are reported separately.
Straightness by autocollimator: step a bridge of length 100 mm along the surface and read the tilt each time; each reading (arc-seconds) × 100 mm × 4.848 µm per ″ per m gives a height increment, summed cumulatively. With readings +2, +1, −1, +3, −2, −1″: increments 0.97, 0.48, -0.48, 1.45, -0.97, -0.48 µm, cumulative profile 0.00, 0.97, 1.45, 0.97, 2.42, 1.45, 0.97 µm; referred to the end-point line the deviations are 0.00, 0.81, 1.13, 0.48, 1.78, 0.65, 0.00 µm, so the straightness error is 1.78 µm (max − min). Flatness is the width of the zone between two parallel planes that encloses the surface (min-zone), found by flats, by autocollimator grids or on a CMM; roundness by the minimum circumscribed, maximum inscribed, minimum-zone or least-squares reference circle, with a rotating-spindle gauge; V-block measurement of an n-lobed section exaggerates or hides the error depending on n and the V angle, which is why it is not a roundness test. Straightness ≠ flatness ≠ parallelism ≠ squareness: each is a different tolerance.
| Parameter | Definition | Worked value |
|---|---|---|
| R_a | (1/L)∫|y|dx | 2.50 µm |
| R_q | √((1/L)∫y²dx) | 2.74 µm |
| Turned R_max | f²/(8r) | 6.25 µm |
| Turned R_a | f²/(32r) | 1.56 µm |
| Autocollimator step | 1″ × 100 mm | 0.485 µm |
- RoughnessFine, tool-marks
- WavinessLonger wavelength
- Form
Surface texture is split into roughness (fine, tool-marks), waviness (longer wavelength) and form, by a cut-off filter (λ_c = 0.8 mm by default, evaluation length 5λ_c = 4 mm). R_a =…
Alignment and Testing of Machine Tools
Alignment (acceptance) tests check the geometry the machine will transfer to every part: geometric tests (Schlesinger's list, ISO 230/1708) measure the machine itself without cutting, and practical tests machine a standard test piece. For a lathe the geometric tests include: levelling of the bed (precision spirit level; sensitivity 0.02 mm/m = 4.1″ per division, so 2.5 divisions over a 200 mm base is 10.0 µm); straightness of the bed ways (straightedge, level or autocollimator); true running of the spindle nose and the taper bore (dial indicator on a test mandrel — radial run-out at the nose and again 300 mm away); parallelism of the spindle axis to the bed ways, vertically and horizontally (dial indicator on a mandrel traversed by the carriage: if the readings differ by 0.02 mm over 300 mm, the error is 0.067 mm/m); parallelism of the tailstock sleeve and alignment of the centres; squareness of the cross-slide to the spindle axis (dial indicator on a face plate or an indicator swept across a surface plate); and lead-screw accuracy against a master. A milling machine adds the squareness of the table to the spindle and the flatness of the table.
| Test | Instrument | Quantity checked |
|---|---|---|
| Bed levelling | Precision level | mm/m twist and slope |
| Spindle true running | Dial indicator and test mandrel | Radial run-out at two stations |
| Spindle parallel to bed | Mandrel on carriage traverse | Deviation per 300 mm, up and sideways |
| Cross-slide squareness | Indicator on face plate | Deviation per diameter |
| Axis positioning | Laser interferometer | Positioning error and repeatability |
Alignment (acceptance) tests check the geometry the machine will transfer to every part: geometric tests (Schlesinger's list, ISO 230/1708) measure the machine itself without cutting, and…
Tolerance Analysis in Manufacturing and Assembly
A tolerance stack-up asks how the tolerances of the parts that make an assembly combine in a gap or an overall length. Worst case (arithmetic) assumes every part at its limit simultaneously: T_total = ΣT_i, which guarantees assembly but forces tight, costly part tolerances. Statistical (RSS, root-sum-square) assumes independent, centred, normally distributed dimensions: T_total = √(ΣT_i²) — much smaller, and valid when many parts are involved. For four stacked dimensions with tolerances ±0.10, ±0.05, ±0.08, ±0.04 mm: worst case ±0.27 mm, RSS ±0.1432 mm, about half. For a housing 100 ± 0.10 mm holding three parts of 30 ± 0.05 mm each, the nominal gap is 100 − 90 = 10 mm; worst case ±(0.10 + 3 × 0.05) = ±0.25, i.e. 9.75 to 10.25 mm; RSS ±√(0.10² + 3 × 0.05²) = ±0.1323 mm. Whichever way a dimension enters, it adds to the tolerance — an inside dimension subtracted from the nominal still adds its tolerance to the stack. Statistical analysis assumes a capable process: with a total tolerance band of 0.10 mm and σ = 0.015 mm, C_p = (USL − LSL)/6σ = 1.11, and about 858 ppm fall outside a centred band; improving σ to 0.010 mm gives C_p = 1.67.
| Method | Total tolerance | Assumption | Result for ±0.10, ±0.05, ±0.08, ±0.04 |
|---|---|---|---|
| Worst case | ΣT_i | All at limit together | ±0.27 mm |
| RSS (statistical) | √(ΣT_i²) | Independent, centred, normal | ±0.1432 mm |
A tolerance stack-up asks how the tolerances of the parts that make an assembly combine in a gap or an overall length. Worst case (arithmetic) assumes every part at its limit…
The Coordinate-Measuring Machine
A CMM measures a part by touching it at points and recording (x, y, z) of the probe from three orthogonal, scale-encoded axes; geometry (diameters, distances, form, position) is then computed from the points. Architectures: bridge (most common, stiff), gantry (large parts), cantilever (open access, smaller), horizontal arm (automotive bodies), articulated arm (portable). Probes: touch-trigger (a kinematic seat that opens on contact and fires a signal, repeatable to ~1 µm), scanning (analog, continuous contact), optical/laser (non-contact). A CMM has 21 rigid-body error components (per axis: 3 linear + 3 angular positioning errors = 6, three axes gives 18, plus 3 squareness errors), which are mapped and compensated in software; its accuracy is quoted as MPE_E = A + L/K, e.g. 1.5 + L/333 µm: for L = 500 mm, 3.0 µm. Temperature (20 °C reference) and a stable environment matter as much as the machine.
Procedure and arithmetic. (1) Qualify the probe: touch a calibration sphere to find the stylus-tip radius and offset. (2) Establish the datum (part co-ordinate system) by the 3-2-1 rule: a plane (3 points), a line (2) and a point (1). (3) Measure features with the minimum number of points the geometry needs — line 2, plane 3, circle 3, sphere 4, cylinder 5, cone 6 — and more to average out form error; the fit is least-squares (default) or minimax (a tolerance-zone fit). (4) Compensate for the stylus tip: the machine records the centre of the ball, so a hole of diameter D probed by a ball of diameter d returns a circle of D − d; with d = 4 mm and a measured path circle of 16.020 mm, the hole is 20.020 mm (for a shaft the ball radius adds outward, D = measured − d). Ignoring the correction would give an error of d, 4 mm. Repeatability, not accuracy, limits how well a CMM compares parts: the same procedure applied to each part cancels most systematic error.
| Feature | Minimum points | Reason |
|---|---|---|
| Line | 2 | Two points define a line |
| Plane | 3 | Three non-collinear points |
| Circle | 3 | Three points fix centre and radius |
| Sphere | 4 | Centre (3) plus radius (1) |
| Cylinder | 5 | Axis (4) plus radius (1) |
| Cone | 6 | Axis, apex and half-angle |

A CMM measures a part by touching it at points and recording (x, y, z) of the probe from three orthogonal, scale-encoded axes; geometry (diameters, distances, form, position) is then…
Key takeaways
- Least count: vernier = main division/vernier divisions, micrometer = pitch/thimble divisions; Abbe's principle favours the micrometer. Sine bar h = L sin θ, and its angle error rises with θ.
- A comparator shows the difference from a master; magnification trades against range; mechanical, optical, electrical (LVDT) and pneumatic types differ in friction, range and contact.
- One fringe = λ/2 of height (0.2947 µm for sodium); straight parallel fringes mean flat; bow a over spacing b gives (a/b)λ/2. Laser interferometer displacement = Nλ/2, limited by air-index compensation.
- R_a is the mean absolute deviation, R_q the rms; turned R_max = f²/8r and R_a ≈ f²/32r. Straightness, flatness, roundness and squareness are different tolerances.
- Stack-up: worst case ΣT, RSS √ΣT²; a CMM needs 2, 3, 3, 4, 5, 6 points for line, plane, circle, sphere, cylinder, cone, compensates the stylus tip and has 21 error components.
Practice questions (24)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
A sine bar of 200 mm centre distance is to be set at 25°. The height of the slip-gauge stack, in mm (three decimals), is:
Numerical answer — type the value.
Show answer
Answer: 84.524
h = L sin θ = 200 × 0.42262 = 84.524 mm. Using tan or cos instead of sin is the usual error.A micrometer has a screw pitch of 0.5 mm and 50 thimble divisions. The sleeve shows 12.5 mm and thimble division 37 lines up with the datum line. The reading is:
Show answer
Answer: A — 12.87 mm
Least count = 0.5/50 = 0.01 mm; reading = 12.5 + 37 × 0.01 = 12.87 mm. 12.37 is a mis-addition of 37 × 0.01 to 12.A comparator has a scale spacing of 1.5 mm per division and each division represents 0.001 mm of spindle movement. Its magnification is:
Show answer
Answer: B — 1500
M = pointer movement/spindle movement = 1.5 mm/0.001 mm = 1500. The device reads only differences from a master, within a short range.
Show the other 21 questions
Using sodium light (λ = 589.3 nm), an optical flat shows fringes bowed by 0.4 of the fringe spacing. The departure from flatness, in µm (three decimals), is:
Numerical answer — type the value.
Show answer
Answer: 0.118
Departure = (a/b)(λ/2) = 0.4 × 0.29465 = 0.118 µm. Using λ instead of λ/2 would double it.In a laser interferometer using a He–Ne laser (632.8 nm) with a single reflector, the displacement of the moving mirror corresponding to N counted fringes is:
Show answer
Answer: B — N × 316.4 nm
The path changes by twice the mirror movement, so each fringe corresponds to λ/2 = 316.4 nm. Quadrature electronics then subdivide this into λ/8 steps.A turned surface is produced with a feed of 0.2 mm/rev and a tool nose radius of 0.8 mm. The ideal arithmetic-mean roughness R_a ≈ f²/(32r), in µm (two decimals), is:
Numerical answer — type the value.
Show answer
Answer: 1.56
R_a = 0.2²/(32 × 0.8) mm = 1.5625 µm; the peak-to-valley is f²/(8r) = 6.25 µm, four times larger.Which statements about machine-tool alignment tests are correct?
Show answer
Answer: A — A laser interferometer can measure positioning error along an axis; C — Parallelism of the spindle axis to the bed is checked with a dial indicator on a test mandrel; D — Geometric tests measure the machine without cutting
Geometric and practical tests complement each other: a test piece shows the combined effect but cannot isolate which error caused it.Four parts stacked in an assembly have tolerances of ±0.10, ±0.05, ±0.08 and ±0.04 mm. The statistical (RSS) tolerance on the overall length, in mm (three decimals), is:
Numerical answer — type the value.
Show answer
Answer: 0.143
√(0.10² + 0.05² + 0.08² + 0.04²) = √0.0205 = 0.143 mm, against ±0.27 mm for the worst case.Which is the minimum number of probe points needed to define a cylinder on a CMM?
Show answer
Answer: D — 5
A cylinder has an axis (4 parameters) and a radius (1) = 5; a circle needs 3, a sphere 4 and a cone 6. In practice many more are taken to average the form error.A micrometer has a screw of 0.5 mm pitch and 50 divisions on the thimble. Its least count, in mm, is _____.
Numerical answer — type the value.
Show answer
Answer: 0.01
Least count = pitch/number of thimble divisions = 0.5/50 = 0.01 mm. Using the pitch alone, 0.5, confuses the travel per revolution with the smallest readable step.On a vernier caliper, 10 vernier scale divisions coincide with 9 main scale divisions, each main division being 1 mm. The least count, in mm, is _____.
Numerical answer — type the value.
Show answer
Answer: 0.1
Least count = 1 main division − 1 vernier division = 1 − 9/10 = 0.1 mm. The value 0.9 is the length of one vernier division, not the difference between the two scales.Slip gauges (gauge blocks) are used mainly as:
Show answer
Answer: D — working standards of length for calibrating and setting instruments
Slip gauges are precision blocks that are wrung together to build up an exact length, serving as the workshop standard to calibrate or set other instruments. Surface roughness needs a stylus instrument, thread form a thread gauge or projector, and angles an angle gauge or sine bar.A sine bar of 100 mm centre distance is to be set at an angle of 30°. The height of the slip-gauge stack, in mm, is _____.
Numerical answer — type the value.
Show answer
Answer: 50
h = L sin θ = 100 × sin 30° = 100 × 0.5 = 50 mm. Using cos 30° (86.6 mm) is the usual slip of picking the wrong trigonometric ratio.The surface roughness parameter Ra is defined as:
Show answer
Answer: C — the arithmetic mean of the absolute deviations of the profile from the mean line
Ra is the arithmetic average of the absolute values of the profile deviations from the mean line over the sampling length. The maximum peak-to-valley height is Rz (or Rt), and the root-mean-square version is Rq. Ra is the most used because it averages out isolated peaks.A shaft dimension is specified as 25 ± 0.02 mm. The tolerance (the total permissible variation), in mm, is _____ (two decimal places).
Numerical answer — type the value.
Show answer
Answer: 0.04
The upper limit is 25.02 and the lower limit 24.98, so the tolerance is 25.02 − 24.98 = 0.04 mm, twice the one-sided deviation. Quoting 0.02 gives only the deviation from the basic size.A sine bar of 200 mm centre distance is to be set at 20°. The slip-gauge stack height, in mm, is _____ (two decimal places).
Numerical answer — type the value.
Show answer
Answer: 68.4
h = L sin θ = 200 × sin 20° = 200 × 0.34202 = 68.40 mm. Working in radians by mistake, sin 20 = 0.913, gives 182.6 mm, so set the calculator to degrees.Using sodium light (λ = 589.3 nm) with an optical flat, a surface shows a departure of 3 fringe spacings from flatness. The height variation, in nm, is _____ (nearest integer).
Numerical answer — type the value.
Show answer
Answer: 884
Each fringe corresponds to a gap change of λ/2 (the light makes a round trip), so 3 fringes = 3 × 589.3/2 = 883.95 ≈ 884 nm. Using λ per fringe, 1768 nm, forgets the double path.A length of 38.375 mm is to be built from an 87-piece slip gauge set containing 1.005, 1.37, 6 and 30 mm pieces among others. Which combination gives the length with the fewest pieces?
Show answer
Answer: C — 30 + 6 + 1.37 + 1.005
Eliminate the last decimal places first: 1.005 removes the 0.005 (38.375 − 1.005 = 37.370); 1.37 removes 0.37 (37.370 − 1.37 = 36.000); 6 leaves 30.000, which is a single 30 mm gauge. So 30 + 6 + 1.37 + 1.005 = 38.375 with four pieces. The other combinations use sizes (2.375, 3.375, 38, 0.375) that are not in a standard 87-piece set.A sine bar of 150 mm centre distance rests on a 40 mm slip-gauge stack. The angle it makes with the surface plate, in degrees, is _____ (one decimal place).
Numerical answer — type the value.
Show answer
Answer: 15.5
sin θ = h/L = 40/150 = 0.2667, so θ = sin⁻¹(0.2667) = 15.5°. Using tan θ = 0.2667 gives 14.9°, which is wrong because the bar's length, not the horizontal run, is the hypotenuse.Two stacked parts have tolerances of ±0.03 mm and ±0.04 mm. The statistical (root-sum-square) tolerance of the stack, in mm, is ± _____ (two decimal places).
Numerical answer — type the value.
Show answer
Answer: 0.05
RSS tolerance = √(0.03² + 0.04²) = √(0.0009 + 0.0016) = √0.0025 = ±0.05 mm. The arithmetic (worst-case) sum is ±0.07 mm, which is more conservative and is not what the statistical method gives.The effective (pitch) diameter of a 60° metric screw thread is measured by the three-wire method using wires of diameter w = 0.866 mm on a thread of pitch p = 1.5 mm. The measurement over the wires is M = 21.5 mm. Using E = M + 0.866p − 3w, the effective diameter, in mm, is _____ (two decimal places).
Numerical answer — type the value.
Show answer
Answer: 20.2
E = M + 0.866p − 3w = 21.5 + 0.866 × 1.5 − 3 × 0.866 = 21.5 + 1.299 − 2.598 = 20.20 mm. The wire size w = 0.866 mm is the best-wire size 0.57735 p for p = 1.5 mm. Forgetting the pitch correction gives 21.5 − 2.598 = 18.90, and using only M gives 21.5, which is the outside measurement over the wires.A laser interferometer using a He–Ne laser (λ = 632.8 nm) with a single retro-reflector measures a displacement of 0.1 mm. The number of fringes counted is _____ (nearest integer).
Numerical answer — type the value.
Show answer
Answer: 316
With a single reflector the path changes by twice the displacement, so each fringe corresponds to a displacement of λ/2 = 316.4 nm. N = 0.1 × 10⁻³/(316.4 × 10⁻⁹) = 316. Forgetting the doubling gives 158 fringes, the usual slip.A 200 mm sine bar is set at 30°. An error of 0.005 mm in the slip-gauge stack height causes an error in the set angle of how many arc-seconds? (1 rad = 206265 arc-seconds; give the answer to two decimal places.)
Numerical answer — type the value.
Show answer
Answer: 5.95
From h = L sin θ, dh = L cos θ dθ, so dθ = dh/(L cos θ) = 0.005/(200 × 0.866) = 2.887 × 10⁻⁵ rad = 2.887 × 10⁻⁵ × 206265 = 5.95 arc-seconds. Ignoring cos θ (dθ = dh/L = 5.16″) understates the error, which grows as the bar is steepened.Which of the following statements about slip gauges are correct? (More than one option may be correct.)
Show answer
Answer: A — Protection slips (wear gauges) are added at the ends of a stack to protect the working gauges; C — A given length should be built with the minimum number of gauges to limit accumulated error; D — Wringing relies on molecular adhesion assisted by a very thin film of oil or moisture
Slip gauges stick together when wrung because of molecular attraction between very flat surfaces and the thin film between them. Each gauge adds its own size error, so fewer pieces mean less accumulated error. Protection slips, made of a wear-resistant material, are put at the ends of the stack so that the working gauges are not worn. Slip gauges are made of hardened, stabilised steel, tungsten carbide or ceramic, not soft brass, which would wear and deform.