Fields II: Divergence and Curl in Practice, Capacitance and Inductance of Simple Configurations, Mutual Inductance, Energy and Force
Capacitance of Simple Configurations
Method: assume a charge Q (or λ per unit length), find D or E from Gauss's law, integrate to get the voltage V, and take C = Q/V. Parallel plate: C = εA/d; with a dielectric slab in series (layers across the gap) 1/C = Σd_i/(ε_iA), with slabs side by side (each covering part of the area) C = Σε_iA_i/d. For 100 cm² plates, 1 mm gap, ε_r = 4: half the gap filled, in series, C = 142 pF; half the area filled, side by side, C = 221 pF (air alone: 88.5 pF). Coaxial (a < b): C′ = 2πε/ln(b/a) per metre — 44.4 pF/m for 1 mm and 3.5 mm in air. Concentric spheres: C = 4πε ab/(b − a); an isolated sphere C = 4πεa (a 10 cm sphere: 11.1 pF). Two parallel wires (radius a, spacing d ≫ a): C′ = πε/ln(d/a) = 6.04 pF/m for d = 0.5 m, a = 5 mm, and exactly πε/cosh⁻¹(d/2a) = 6.04 pF/m; a wire at height h above ground: C′ = 2πε/ln(2h/a) — twice the pair value for the same d/2 = h, by the method of images (the ground acts as the image wire at −h).
Energy and force. W = ½CV²; for a parallel-plate capacitor at 1 kV with C = 88.5 pF, W = 44.3 µJ. At constant voltage the force on a plate is F = ½V² dC/dx; for plates of 100 cm² with a gap x = 1 mm, dC/dx = −εA/x² and |F| = ½V²εA/x² = 0.0443 N — the electrostatic force that pulls capacitive MEMS sensors and electrostatic voltmeters. At constant charge the same force is F = −dW/dx|_Q, the same value. Field strength limits the design: the maximum field in a coaxial cable is at the inner conductor, E_max = V/[a ln(b/a)], minimised for b/a = e (2.718), the classic optimisation for a cable of fixed outer radius; the electric stress in a graded or layered dielectric is highest in the layer of lowest permittivity.
| Configuration | Capacitance | Example |
|---|---|---|
| Parallel plate | εA/d | 88.5 pF (100 cm², 1 mm) |
| Coaxial | 2πε/ln(b/a) per m | 44.4 pF/m |
| Concentric spheres | 4πε ab/(b − a) | 5 cm and 10 cm: 11.1 pF |
| Two parallel wires | πε/ln(d/a) per m | 6.04 pF/m |
| Wire over ground | 2πε/ln(2h/a) per m | 7.32 pF/m (h = 10 m, a = 10 mm) |
Method: assume a charge Q (or λ per unit length), find D or E from Gauss's law, integrate to get the voltage V, and take C = Q/V. Parallel plate: C = εA/d; with a dielectric slab in series…
Inductance of Simple Configurations
Method: assume a current I, find B (or H) from Ampère's law, integrate to get the flux linked by the circuit, and take L = Nφ/I (the flux linkage per ampere), or from the energy, W = ½LI². Long solenoid: B = μNI/l, so L = μN²A/l — with N = 500, A = 4 cm², l = 0.25 m in air: 0.503 mH (a magnetic core multiplies it by μ_r). Toroid (mean radius R, section A ≪ R²): H = NI/(2πR), L = μN²A/(2πR) — N = 1000, A = 1 cm², R = 0.1 m: 0.20 mH. Coaxial line: the external flux between the conductors gives L′ = (μ/2π)ln(b/a) per metre (251 nH/m for b/a = 3.5), and the flux inside a solid inner conductor adds the internal inductance μ/(8π) = 50 nH/m, independent of radius. Two-wire line (spacing d, radius a): the external part is L′ = (μ/π)ln(d/a) = 1.842 µH/m for d = 0.5 m, a = 5 mm, and adding the internal contributions of both wires, 2 × μ/(8π) = μ/(4π) = 0.1 µH/m, gives 1.942 µH/m (internal part usually neglected at high frequency by skin effect).
| Configuration | Inductance | Example |
|---|---|---|
| Long solenoid | μN²A/l | 0.503 mH |
| Toroid | μN²A/(2πR) | 0.20 mH |
| Coaxial (external), per m | (μ/2π)ln(b/a) | 251 nH/m |
| Two-wire (external), per m | (μ/π)ln(d/a) | 1.842 µH/m |
| Internal, solid wire, per m | μ/(8π) | 50 nH/m |
- Assume a charge Q
- Gauss's law: D or E
- Integrate to get V
- C = Q/V
- Assume a current I
- Ampère's law: B or H
- Integrate to get flux linked
- L = Nφ/I
Method: assume a current I, find B (or H) from Ampère's law, integrate to get the flux linked by the circuit, and take L = Nφ/I (the flux linkage per ampere), or from the energy, W = ½LI².…
Mutual Inductance, Coupling, Energy and Force
Mutual inductance M = N₂φ₂₁/I₁ is the flux of coil 1 linking coil 2 per unit current, and M₁₂ = M₂₁. For two coaxial windings on the same core or one inside the other, M = μN₁N₂A/l. With N₁ = 1000 (outer), N₂ = 100 (inner) on a common length l = 0.5 m and inner area A = 10 cm² in air: L₁ = μN₁²A/l = 2.513 mH, L₂ = 0.025 mH, and M = 0.251 mH (= √(L₁L₂), so k = 1.00, perfect coupling because the inner coil sees all the outer flux). The coupling coefficient k = M/√(L₁L₂) ≤ 1. Series connection: L = L₁ + L₂ ± 2M (aiding/opposing). The induced emf is e₂ = −M di₁/dt. Energy: W = ½L₁I₁² + ½L₂I₂² ± MI₁I₂. Force between two long parallel conductors carrying I₁ and I₂ at spacing d: F/l = μI₁I₂/(2πd) = 2 × 10⁻⁷ I₁I₂/d N/m — attractive for currents in the same direction: 100 A and 100 A at 0.5 m give 0.0040 N/m (the definition of the ampere uses this at 1 A, 1 m, 2 × 10⁻⁷ N/m).
Energy and force by differentiating. For a lossless magnetic system the force on a movable part is F = ½I² dL/dx at constant current (or −dW/dx at constant flux linkage). A solenoid with a plunger has L rising as the plunger enters, so the force pulls it in; an electromagnet with an air gap g has L ∝ 1/g and a pull F = B²A/(2μ₀) per pole face: at B = 1 T and A = 4 cm², two faces pull with F = 2 × (1²/(2 × 4π × 10⁻⁷)) × 4 × 10⁻⁴ = 318 N, about the weight of 32 kg, spread across the two 4 cm² faces. In an iron core the flux density saturates near 1.5–2 T, so the force per area saturates near 0.9–1.6 MN/m². The same F = ½I² dL/dx explains moving-iron ammeters and relays; for rotating machines the torque is T = ½I² dL/dθ (the reluctance torque).
Mutual inductance M = N₂φ₂₁/I₁ is the flux of coil 1 linking coil 2 per unit current, and M₁₂ = M₂₁. For two coaxial windings on the same core or one inside the other, M = μN₁N₂A/l. With N₁…
Key takeaways
- div F is the source density, curl F the circulation density; ∮F·dS = ∫∇·F dV and ∮F·dl = ∫∇×F·dS; ∇×(∇V) = 0 and ∇·(∇×F) = 0.
- Capacitance: Gauss for E, integrate for V, C = Q/V; plate εA/d, coax 2πε/ln(b/a), spheres 4πε ab/(b − a), two wires πε/ln(d/a); series layers add as 1/C, parallel areas add as C.
- Inductance: Ampère for B, flux linkage per ampere; solenoid μN²A/l, toroid μN²A/(2πR), coax (μ/2π)ln(b/a), two-wire (μ/π)ln(d/a), plus μ/(8π) internal per wire.
- Mutual inductance M = k√(L₁L₂) with k ≤ 1; series aiding/opposing L = L₁ + L₂ ± 2M; force between parallel currents 2 × 10⁻⁷ I₁I₂/d N/m.
- Force from energy: F = ½V² dC/dx (electric) and ½I² dL/dx (magnetic); magnet pull per face B²A/2μ₀.
Practice questions (24)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
For the vector field F = (x²y, yz, xz²), the divergence at the point (1, 2, 3) is:
Numerical answer — type the value.
Show answer
Answer: 13
∇·F = 2xy + z + 2xz = 4 + 3 + 6 = 13. The curl there is (−y, −z², −x²) = (−2, −9, −1).Which statement is true for every electrostatic field E = −∇V?
Show answer
Answer: A — ∇×E = 0
A gradient field has zero curl (∇×∇V = 0), so electrostatic fields are conservative. Its divergence is ρ/ε, not zero where charge exists.A coaxial cable with inner radius 1 mm and outer radius 3.5 mm has air between the conductors. Its capacitance per metre, in pF (one decimal), is:
Numerical answer — type the value.
Show answer
Answer: 44.4
C′ = 2πε₀/ln(b/a) = 2π × 8.854 × 10⁻¹²/ln 3.5 = 44.4 pF/m. Filling it with polyethylene (ε_r = 2.3) would multiply this by 2.3.
Show the other 21 questions
Parallel plates of area 100 cm² and gap 1 mm have a dielectric of ε_r = 4 filling the lower half of the gap (layers in series with the air above). The capacitance in pF (nearest integer) is:
Numerical answer — type the value.
Show answer
Answer: 142
1/C = (0.5 mm/4 + 0.5 mm)/(ε₀A): C = ε₀A/0.625 mm = 142 pF. A completely filled gap would give 354 pF; air alone 88.5 pF.Two long parallel wires of radius a are spaced d apart (d ≫ a). Their capacitance per unit length is approximately:
Show answer
Answer: A — πε/ln(d/a)
Each wire has a potential ±(λ/2πε)ln(d/a), so V = (λ/πε)ln(d/a) between them and C′ = λ/V = πε/ln(d/a). The coaxial value 2πε/ln(b/a) differs by the factor 2.A 500-turn air-core solenoid of cross-section 4 cm² and length 0.25 m has a self-inductance, in mH (three decimals), of:
Numerical answer — type the value.
Show answer
Answer: 0.503
L = μ₀N²A/l = 4π × 10⁻⁷ × 250 000 × 4 × 10⁻⁴/0.25 = 0.503 mH. Doubling the turns quadruples L.The external inductance per unit length of a two-wire line of spacing d and wire radius a is:
Show answer
Answer: C — (μ₀/π) ln(d/a)
The loop formed by the out and return wires gives L′ = (μ₀/π)ln(d/a) (twice the coaxial (μ₀/2π)ln(b/a) form, one wire each way); the internal flux adds μ₀/4π more.Two coaxial coils (N₁ = 1000 outer, N₂ = 100 inner) share a length of 0.5 m and an inner area of 10 cm² in air. Their mutual inductance in mH (three decimals) is:
Numerical answer — type the value.
Show answer
Answer: 0.251
M = μ₀N₁N₂A/l = 4π × 10⁻⁷ × 1000 × 100 × 10⁻³/0.5 = 0.251 mH; it equals √(L₁L₂) because the coupling is perfect (k = 1).Two long parallel conductors carry 100 A each in the same direction, 0.5 m apart. The force per metre is:
Show answer
Answer: B — 0.004 N/m, attractive
F/l = 2 × 10⁻⁷ × 100 × 100/0.5 = 0.004 N/m, and parallel currents attract (opposite currents repel).Which statements about force and energy in electric and magnetic systems are correct?
Show answer
Answer: A — The force in a magnetic system at constant current is ½I² dL/dx; B — The pull per pole face of a magnet is B²A/2μ₀; D — The force on a plate at constant voltage is ½V² dC/dx
k = M/√(L₁L₂) cannot exceed 1: no coil can link more flux than another coil produces.The divergence of the vector field F = (2x, 3y, 4z) is ____.
Numerical answer — type the value.
Show answer
Answer: 9
∇·F = ∂(2x)/∂x + ∂(3y)/∂y + ∂(4z)/∂z = 2 + 3 + 4 = 9, the same everywhere. The tempting 24 multiplies the coefficients instead of adding the partial derivatives.For any twice-differentiable scalar field V, the curl of its gradient, ∇ × (∇V), is
Show answer
Answer: C — always zero
Mixed partial derivatives commute, so every component of ∇ × ∇V cancels; this is why an electrostatic field E = −∇V is irrotational. The tempting ∇²V is the divergence of the gradient, not its curl.An air-filled parallel-plate capacitor has plates of 0.01 m² separated by 1 mm (ε₀ = 8.854 x 10^(-12) F/m). Its capacitance, in pF to one decimal place, is ____.
Numerical answer — type the value.
Show answer
Answer: 88.5
C = ε₀A/d = 8.854×10⁻¹² × 0.01/10⁻³ = 88.5 pF. The tempting 0.0885 pF leaves d in millimetres. Substituting the answer back into the relation confirms it.Capacitors of 2 µF and 3 µF are connected in series. The equivalent capacitance, in µF, is ____.
Numerical answer — type the value.
Show answer
Answer: 1.2
In series the reciprocals add: 1/C = 1/2 + 1/3, so C = 6/5 = 1.2 µF. The tempting 5 µF is the parallel sum. Substituting the answer back into the relation confirms it.A coil of 100 turns on a fixed core has an inductance of 1 mH. If it is rewound with 300 turns on the same core, its inductance, in mH, is ____.
Numerical answer — type the value.
Show answer
Answer: 9
L = N²/S with S fixed, so tripling N multiplies L by 9. The tempting 3 mH scales linearly with turns. Substituting the answer back into the relation confirms it.The coefficient of coupling k between two coils is defined as M/√(L₁L₂). Its possible values lie in the range
Show answer
Answer: A — 0 ≤ k ≤ 1
Stored energy must stay non-negative for every pair of currents, which forces M² ≤ L₁L₂, so 0 ≤ k ≤ 1 (k = 1 is perfect coupling). The tempting unbounded range would allow negative stored energy.The z-component of the curl of F = (−y, x, 0) is ____.
Numerical answer — type the value.
Show answer
Answer: 2
(∇ × F)_z = ∂F_y/∂x − ∂F_x/∂y = 1 − (−1) = 2, the field being a uniform rotation. The tempting 0 subtracts the derivatives in the wrong order.An isolated conducting sphere of radius 0.1 m is in air (ε₀ = 8.854 x 10^(-12) F/m). Its capacitance, in pF to two decimal places, is ____.
Numerical answer — type the value.
Show answer
Answer: 11.13
C = 4πε₀R = 4π × 8.854×10⁻¹² × 0.1 = 11.13 pF, the outer conductor being at infinity. The tempting 1.11 pF omits the factor 4π, using ε₀R.The energy density of a magnetic field of 1 T in air, in kJ/m³ to one decimal place, is ____.
Numerical answer — type the value.
Show answer
Answer: 397.9
w = B²/(2μ₀) = 1/(2 × 4π×10⁻⁷) = 3.979×10⁵ J/m³ = 397.9 kJ/m³. The tempting 795.8 kJ/m³ omits the factor of one half.Two coils of 4 mH and 9 mH have a coupling coefficient of 0.8. Their mutual inductance, in mH, is ____.
Numerical answer — type the value.
Show answer
Answer: 4.8
M = k√(L₁L₂) = 0.8 × 6 = 4.8 mH. The tempting 28.8 mH uses kL₁L₂ without the square root. Substituting the answer back into the relation confirms it.The vector field F = (x, y, z) passes through the surface of the unit cube 0 ≤ x, y, z ≤ 1. The net outward flux is ____.
Numerical answer — type the value.
Show answer
Answer: 3
By the divergence theorem the flux is ∭∇·F dV = 3 × 1 = 3; directly, the three faces at x, y or z = 1 each carry flux 1 and the faces through the origin carry none. The tempting 6 counts flux of 1 through all six faces.Parallel plates of area 100 cm² and gap 1 mm have a dielectric of relative permittivity 4 filling the full gap over half the plate area, the other half being air. The capacitance, in pF to one decimal place, is ____.
Numerical answer — type the value.
Show answer
Answer: 221.4
The two halves are side by side, i.e. in parallel: C = ε₀(A/2)(1 + 4)/d = 8.854×10⁻¹² × 0.005 × 5/10⁻³ = 221.4 pF. The tempting 141.7 pF treats them as layers in series, which is the arrangement when the dielectric fills half the gap.An air coaxial line has an inner conductor of radius 1 mm and an outer conductor of inner radius 5 mm. Neglecting internal inductance, its inductance per metre, in µH to three decimal places, is ____.
Numerical answer — type the value.
Show answer
Answer: 0.322
L = (μ₀/2π) ln(b/a) = 2×10⁻⁷ × ln 5 = 0.322 µH/m. The tempting 0.140 µH/m uses log₁₀ 5 instead of the natural logarithm.Coils with L₁ = 4 H and L₂ = 9 H have M = 3 H and carry I₁ = 1 A and I₂ = 2 A with their fluxes aiding. The total stored magnetic energy, in J, is ____.
Numerical answer — type the value.
Show answer
Answer: 26
W = ½L₁I₁² + ½L₂I₂² + MI₁I₂ = 2 + 18 + 6 = 26 J (the quadratic form ½IᵀLI). The tempting 23 J writes the mutual term as ½MI₁I₂, and 14 J subtracts it as for opposing fluxes.