Process Calculations at Working Depth: Unsteady and Energy Balances, Multiphase and Multicomponent Separations, Combustion and Reaction Stoichiometry, Recycle-Bypass-Purge Numbers and Degree-of-Freedom Counting
Multicomponent and Multiphase Balances: Columns, Dryers, Crystallisers and Flash
Write one balance per component and one total balance; choose a basis first. Binary distillation: F = 100 kmol/h, x_F = 0.40, distillate x_D = 0.95, bottoms x_B = 0.05. Total F = D + B and component F x_F = D x_D + B x_B give D = F(x_F − x_B)/(x_D − x_B) = 38.89 kmol/h and B = 61.11 kmol/h; the recovery of the light component in the distillate is D x_D/(F x_F) = 92.4%. Drying: 1000 kg of wet solid at 40% moisture (wet basis) has 600 kg bone-dry solid; at 10% moisture the product is 600/0.9 = 666.7 kg, so 333.3 kg of water is removed — the dry solid is the tie component and moisture on a wet basis changes with it, so convert to dry basis when in doubt.
Evaporative crystalliser: 1000 kg of 25 wt% salt solution loses 400 kg of water by evaporation and is cooled to where the saturated solution holds 30 g salt per 100 g water (crystals anhydrous). Salt 250 kg, water 750 kg → 350 kg water remains and dissolves 0.30 × 350 = 105 kg, so crystals = 250 − 105 = 145 kg. Isothermal flash (a multiphase problem): equimolar binary, K₁ = 2.0, K₂ = 0.5. The Rachford–Rice equation Σ z_i(K_i − 1)/[1 + (V/F)(K_i − 1)] = 0 is solved for V/F = 0.500; then x₁ = z₁/[1 + (V/F)(K₁ − 1)] = 0.3333 and y₁ = K₁x₁ = 0.6667. Check: Σy − Σx = 0.
| Unit | Given | Result |
|---|---|---|
| Binary column | F=100, x_F=0.40, x_D=0.95, x_B=0.05 | D = 38.89, B = 61.11 kmol/h |
| Dryer | 1000 kg at 40% → 10% moisture | product 666.7 kg; water 333.3 kg |
| Crystalliser | 25% solution, evaporate 400 kg, solubility 30 g/100 g | crystals 145 kg |
| Flash | z = 0.5, K = 2.0 and 0.5 | V/F = 0.500; x₁ = 0.3333; y₁ = 0.6667 |
Write one balance per component and one total balance; choose a basis first. Binary distillation: F = 100 kmol/h, x_F = 0.40, distillate x_D = 0.95, bottoms x_B = 0.05. Total F = D + B and…
Reacting Systems: Tie Components, Extent of Reaction and Combustion
In a reacting system write element (atomic) balances, or component balances with the extent of reaction ξ (n_i = n_i0 + ν_iξ). Ammonia synthesis: feed 100 mol N₂ and 300 mol H₂, 25% conversion of N₂ (ξ = 25): N₂ = 75, H₂ = 225, NH₃ = 50, total 350 mol, so y_NH₃ = 14.29%. The heat of reaction from formation data is ΔH°_rxn = ΣνΔH°_f; for CH₄ + 2O₂ → CO₂ + 2H₂O(l) with ΔH°_f = −74.8, −393.5 and −285.8 kJ/mol: ΔH° = −393.5 + 2(−285.8) − (−74.8) = -890.3 kJ/mol. Conversion, yield and selectivity are different ratios: conversion = reacted/fed, yield = desired formed/theoretical (or fed), selectivity = desired formed/undesired formed.
Combustion with excess air. Burn 100 mol CH₄ with 20% excess air: theoretical O₂ = 200 mol, supplied = 240 mol, with N₂ = 240 × 79/21 = 902.86 mol (N₂ is the tie component: it passes through unchanged). Complete combustion gives CO₂ 100, H₂O 200, O₂ 40, N₂ 902.86: total wet gas 1242.86, dry gas 1042.86 mol, so the Orsat (dry) analysis is CO₂ 9.59%, O₂ 3.84%, N₂ 86.58%. If 10% of the carbon burns only to CO (CO 10, CO₂ 90) the leftover O₂ is 240 − 180 − 15 = 45 mol and the dry gas is 1047.86 mol. Finding excess air from analysis: if a CO-free dry flue gas is 9.5% CO₂, 4.0% O₂ and 86.5% N₂, the O₂ supplied is 86.5 × 21/79 = 22.99, consumed = 18.99, so excess air = 4.0/18.99 = 21.1%.
| Quantity | Value |
|---|---|
| Dry flue gas, CH₄ + 20% excess air: CO₂ / O₂ / N₂ | 9.59 / 3.84 / 86.58 % |
| Excess air from 9.5/4.0/86.5 analysis | 21.1 % |
| ΔH° of methane combustion (liquid water) | -890.3 kJ/mol |
| NH₃ mole fraction at 25% conversion | 14.29 % |
In a reacting system write element (atomic) balances, or component balances with the extent of reaction ξ (n_i = n_i0 + ν_iξ). Ammonia synthesis: feed 100 mol N₂ and 300 mol H₂, 25%…
Recycle, Bypass, Purge and Degrees of Freedom
Recycle raises overall conversion above single-pass conversion. For A → B with 100 mol/h fresh A, 25% single-pass conversion and a separator that returns all unreacted A except 5 mol/h (95% overall conversion): unreacted A leaving the reactor = 0.75(100 + R) and R = that minus 5, so 0.25R = 75 − 5 and R = 280 mol/h; the reactor feed is 380 mol/h, the reactor works at a far higher throughput than the fresh feed. A purge is needed when an inert (or by-product) enters with the fresh feed and has no exit but the purge: with 0.5 mol/h of inert in the fresh feed and the recycle limited to 5 mol% inert, purge P = 0.5/0.05 = 10 mol/h, which also carries 9.5 mol/h of reactant, a cost. A bypass skips a unit: a wastewater stream of 500 ppm passes a unit that removes 90% (to 50 ppm) and must meet 100 ppm; the bypass fraction x satisfies (1 − x)(50) + x(500) = 100, so x = 0.1111.
Degrees of freedom = number of variables − number of independent equations (balances, specifications, relations); a well-posed problem has zero. For a steady mixer of three components, two inlet and one outlet streams, written as component flows: 9 variables, 3 balances, so 6 specifications are needed. For a reacting unit add one variable (the extent) per independent reaction. The Gibbs phase rule for non-reacting systems is F = C − P + 2; with reactions C = S − R (species minus independent reactions) and any further stoichiometric constraint (such as equimolar gas products) reduces C again. Pure water at its triple point: C = 1, P = 3, F = 0; boiling water: F = 1; CaCO₃ ⇌ CaO + CO₂ (S = 3, R = 1, C = 2, P = 3): F = 1; NH₄Cl(s) ⇌ NH₃ + HCl with the gases equimolar (C = 3 − 1 − 1 = 1, P = 2): F = 1.
| System | C | P | F = C − P + 2 |
|---|---|---|---|
| Water at the triple point | 1 | 3 | 0 |
| Boiling water | 1 | 2 | 1 |
| CaCO₃ ⇌ CaO + CO₂ | 2 | 3 | 1 |
| NH₄Cl(s) ⇌ NH₃ + HCl, equimolar gases | 1 | 2 | 1 |
| Ice, brine and salt (eutectic), pressure free | 2 | 3 | 1 |
Recycle raises overall conversion above single-pass conversion. For A → B with 100 mol/h fresh A, 25% single-pass conversion and a separator that returns all unreacted A except 5 mol/h (95%…
Key takeaways
- Accumulation = input − output + generation − consumption; a well-mixed tank with no reaction follows C = C_in(1 − e^(−t/τ)), τ = V/F, and reaches 90% in 2.3 τ.
- Write one balance per component plus a total; use the unreacted component as the tie; moisture on a wet basis moves with the solid, so go to dry basis.
- Reacting systems: n_i = n_i0 + ν_iξ; air is 21 mol% O₂, so N₂ = 79/21 of the O₂ supplied, and the N₂ is the tie to find excess air from a flue-gas analysis.
- Recycle lifts overall above single-pass conversion; a purge fixes the inert level at P = (inert fed)/(allowed fraction); a bypass is solved by mixing the treated and untreated streams.
- Degrees of freedom = variables − independent equations (zero when well posed); Gibbs rule F = C − P + 2 with C = S − R − (extra constraints).
Practice questions (24)
Attempt each one before opening the answer. Every explanation names the tempting wrong option as well as the right one, because that is where marks are lost.
A well-mixed tank of 2000 L receives 50 L/min of brine at 10 g/L, starting with pure water and discharging 50 L/min. The salt concentration after 60 min, in g/L (two decimals), is:
Numerical answer — type the value.
Show answer
Answer: 7.77
τ = V/F = 40 min; C = 10(1 − e^(−1.5)) = 7.77 g/L.How much saturated steam (latent heat 2257 kJ/kg) is needed, in kg/h (one decimal), to heat 1000 kg/h of water from 25 °C to 80 °C (C_p = 4.18 kJ/kg·K), if the steam condenses completely?
Numerical answer — type the value.
Show answer
Answer: 101.9
m_s = 1000 × 4.18 × 55/2257 = 101.9 kg/h.A distillation column treats F = 100 kmol/h of 40 mol% feed to give a distillate of 95 mol% and bottoms of 5 mol% of the light component. The distillate rate in kmol/h (two decimals) is:
Numerical answer — type the value.
Show answer
Answer: 38.89
D = F(x_F − x_B)/(x_D − x_B) = 100(0.35)/0.90 = 38.89 kmol/h; B = 61.11.
Show the other 21 questions
1000 kg of solid containing 40% moisture (wet basis) is dried to 10% moisture (wet basis). The mass of water removed, in kg (one decimal), is:
Numerical answer — type the value.
Show answer
Answer: 333.3
Dry solid = 600 kg (tie). Product = 600/0.9 = 666.7 kg; water removed = 1000 − 666.7 = 333.3 kg.An equimolar binary mixture is flashed isothermally; K₁ = 2.0 and K₂ = 0.5. The vapour fraction V/F (three decimals) is:
Numerical answer — type the value.
Show answer
Answer: 0.500
Rachford–Rice: 0.5(1)/(1 + V) + 0.5(−0.5)/(1 − 0.5V) = 0 → V/F = 0.500.Methane is burnt with 20% excess air. The CO₂ content of the dry flue gas in mol% (two decimals), assuming complete combustion, is:
Numerical answer — type the value.
Show answer
Answer: 9.59
Per 100 mol CH₄: dry gas = CO₂ 100 + O₂ 40 + N₂ 902.86 = 1042.86; CO₂ = 9.59%.In a combustion problem where the flue-gas analysis is known, the component used as the tie to find the air supplied is:
Show answer
Answer: D — nitrogen, which passes through unchanged
N₂ is inert in ordinary combustion, so moles of N₂ in the flue equal moles in the air; O₂ supplied follows from the 21/79 ratio.A reactor converts 25% of A per pass; fresh feed is 100 mol/h and the separator sends back all unreacted A except 5 mol/h (95% overall conversion). The recycle flow in mol/h is:
Numerical answer — type the value.
Show answer
Answer: 280
0.75(100 + R) − 5 = R → 0.25R = 70 → R = 280 mol/h; reactor feed 380 mol/h.A fresh feed carries 0.5 mol/h of inert, which can leave only in a purge; the recycle loop must stay at 5 mol% inert. The purge rate in mol/h is:
Numerical answer — type the value.
Show answer
Answer: 10
The inert leaves only in the purge, so P × 0.05 = 0.5 → P = 10 mol/h.Which of the following are correct?
Show answer
Answer: A — CaCO₃ ⇌ CaO + CO₂ in a closed vessel has F = 1; D — Water at its triple point has F = 0 by the Gibbs phase rule
The triple point of a pure substance is invariant (C = 1, P = 3); the carbonate has C = 2 and P = 3 so F = 1. A well-posed problem has zero degrees of freedom, and a purge is needed precisely when an inert is present.100 kg of water (c_p = 4.18 kJ/kg·K) is heated from 20 °C to 80 °C. The heat required, in kJ, is ____.
Numerical answer — type the value.
Show answer
Answer: 25080
Q = mc_pΔT = 100 × 4.18 × 60 = 25 080 kJ. Using 80 °C instead of the 60 K rise (33 440 kJ) counts heat from 0 °C that was never supplied.The moles of O₂ needed to burn 1 mol of CH₄ completely to CO₂ and H₂O are ____.
Numerical answer — type the value.
Show answer
Answer: 2
CH₄ + 2O₂ → CO₂ + 2H₂O: 1 O₂ for the carbon and 1 for the four hydrogens. Answering 1 covers only the carbon; the air needed is 2/0.21 = 9.52 mol.Taking air as 21 mol% O₂, the theoretical air needed to burn 1 mol of carbon to CO₂, in mol (two decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 4.76
C + O₂ → CO₂ needs 1 mol O₂, carried in 1/0.21 = 4.76 mol air. Multiplying by 0.21 (0.21 mol) inverts the dilution.In a flash drum a component has vapour mole fraction 0.6 and liquid mole fraction 0.3. Its K-value is ____.
Numerical answer — type the value.
Show answer
Answer: 2
K = y/x = 0.6/0.3 = 2, so the component favours the vapour. Inverting it (0.5) would describe a heavy component.The standard heat of a reaction can be found from standard heats of formation as
Show answer
Answer: A — Σ(ν ΔH_f°) of products − Σ(ν ΔH_f°) of reactants
By Hess's law the reaction is "un-form the reactants, form the products", so ΔH_r° = Σν_pΔH_f,p − Σν_rΔH_f,r. The reversed order is the rule for heats of COMBUSTION, the usual mix-up.A burner receives 12 mol of O₂ where 10 mol are theoretically needed. The percent excess air is ____.
Numerical answer — type the value.
Show answer
Answer: 20
Excess = (supplied − theoretical)/theoretical × 100 = 2/10 × 100 = 20 %. Dividing by the supplied amount (16.7 %) uses the wrong base.2 mol H₂ and 2 mol O₂ are fed for 2H₂ + O₂ → 2H₂O. The limiting reactant is
Show answer
Answer: D — H₂
Feed ratio O₂/H₂ = 1 exceeds the stoichiometric 0.5, so H₂ runs out first and O₂ is 100 % in excess. Equal moles look "balanced" but the coefficients are 2 : 1, which is the trap.With ΔH_f° (kJ/mol) = −74.8 for CH₄, −393.5 for CO₂ and −285.8 for H₂O(l), the standard heat of CH₄ + 2O₂ → CO₂ + 2H₂O(l), in kJ/mol (one decimal), is ____.
Numerical answer — type the value.
Show answer
Answer: -890.3
ΔH = −393.5 + 2(−285.8) − (−74.8) = -890.3 kJ/mol (O₂ has ΔH_f° = 0). Forgetting the coefficient 2 on water gives −604.5, and adding CH₄'s value instead of subtracting gives −1039.9.A column fed 100 mol/h at z_F = 0.5 gives D = 50 mol/h at x_D = 0.9. The percent recovery of the light component in the distillate is ____.
Numerical answer — type the value.
Show answer
Answer: 90
Recovery = Dx_D/(Fz_F) = 45/50 = 90 %. Quoting the purity x_D = 90 % happens to coincide here, but purity and recovery are different specifications in general (the bottoms here hold 0.1 purity).For 2A → B, 10 mol of A is fed and 6 mol of A remains. The extent of reaction, in mol, is ____.
Numerical answer — type the value.
Show answer
Answer: 2
n_A = n_A0 − 2ξ, so ξ = (10 − 6)/2 = 2 mol, producing 2 mol B. Answering 4 gives the moles of A consumed, forgetting to divide by its stoichiometric coefficient.A reactor converts 40 % of A per pass. Fresh feed is 100 mol/h of A, and all unreacted A is recovered and recycled (no purge). The recycle rate, in mol/h, is ____.
Numerical answer — type the value.
Show answer
Answer: 150
At steady state all 100 mol/h must react, so reactor feed = 100/0.4 = 250 and recycle = 150 mol/h. Answering 60 takes the unreacted part of the fresh feed only, missing that recycled A also passes through unreacted.Carbon is burnt completely with 50 % excess air (21 % O₂, 79 % N₂). The CO₂ content of the flue gas, in mol% (two decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 14.00
Per mol C: O₂ fed 1.5, N₂ = 1.5 × 79/21 = 5.643; flue = 1 CO₂ + 0.5 O₂ + 5.643 N₂ = 7.143 mol, so CO₂ = 14.00 %. With theoretical air it would be 21 %; forgetting the excess O₂ in the flue gas gives a higher value.Methane is burnt completely with 10 % excess air (21 % O₂). The CO₂ content of the WET flue gas (water counted as vapour), in mol% (two decimals), is ____.
Numerical answer — type the value.
Show answer
Answer: 8.71
Per mol CH₄: O₂ fed 2.2, N₂ = 8.276; wet flue = 1 CO₂ + 2 H₂O + 0.2 O₂ + 8.276 N₂ = 11.476 mol, so CO₂ = 8.71 %. Leaving out the water gives the dry (Orsat) value 10.55 %, the tempting answer.Which statements about the phase rule are correct?
Show answer
Answer: A — A pure substance at its triple point has F = 0.; B — With r independent reactions, F = C − P + 2 − r.; D — A binary azeotrope at a fixed pressure has no remaining degrees of freedom.
Each reaction equilibrium removes one freedom; the triple point is 1 − 3 + 2 = 0; an azeotrope (x = y) adds a constraint, so at fixed P: 2 − 2 + 2 − 1 − 1 = 0. A single-phase pure gas has F = 1 − 1 + 2 = 2 (both T and P can vary), so the last statement is the trap.